Product Overview
Global Healthcare Medical GHM HT-115A US is a high-throughput, semi-automated urine analyzer engineered for hospital laboratories, polyclinics, and high-volume testing centers that require rapid, reliable routine urinalysis without the footprint of a fully automated track system. The analyzer delivers a testing speed of 514 tests per hour—approximately one result every 7 seconds—supporting efficient processing of large daily workloads from a compact benchtop platform.
The system utilizes high-brightness LED light source technology with reflectance photometry, detecting color changes on reagent strips across four measurement wavelengths (525 nm, 572 nm, 610 nm, and 660 nm) to deliver qualitative and semi-quantitative results for up to 14 urine parameters, including leukocytes, nitrite, urobilinogen, protein, pH, blood, specific gravity, ketone, bilirubin, glucose, vitamin C, creatinine, calcium, and microalbuminuria.
The analyzer is compatible with 8A, 10A, 11A, 12A, 13A, and 14A reagent strip formats, providing laboratories with flexibility in menu configuration and cost management. An optional 8-inch touchscreen is available for direct touch input, while the standard configuration features a high-brightness LCD display for clear result visibility.
On-board data storage accommodates up to 100,000 patient results in the standard configuration, alongside dedicated storage for quality control records, supporting retrospective review and data management. RS-232 and parallel ports enable connection to laboratory information systems (LIS/HIS) and external printers, while the built-in high-speed thermal printer (55–57 mm paper) delivers immediate hard-copy results. An integrated waste tray automatically collects used strips, supporting a clean and efficient workflow.
The analyzer operates on AC 100–240 V, 50/60 Hz with 65 VA power consumption and is designed for storage across a wide temperature and humidity range (−40°C to 55°C, 10%–95% RH, non-condensing). With dimensions of 380 × 380 × 275 mm and a weight of 6.5 kg, the GHM HT-115A US integrates into space-constrained laboratory environments while delivering high-throughput routine urinalysis capability.
Key Features & Benefits
High Throughput – 514 Tests Per Hour
The analyzer delivers a testing speed of 514 tests per hour, supporting efficient processing of high-volume routine urinalysis workloads in hospital and reference laboratory settings.
| Feature | Benefit |
|---|---|
| 514 tests/hour throughput | High-volume processing capability |
| ~7 seconds per test | Rapid turnaround for routine screening |
| Batch-friendly workflow | Suitable for large daily testing schedules |
14-Parameter Urinalysis – Comprehensive Routine Screening Panel
The system delivers qualitative or semi-quantitative results for up to 14 parameters: Leukocytes (LEU), Nitrite (NIT), Urobilinogen (URO), Protein (PRO), pH, Blood (BLD), Specific Gravity (SG), Ketone (KET), Bilirubin (BIL), Glucose (GLU), Vitamin C (VC), Creatinine (CR), Calcium (CA), and Microalbuminuria (MALB) .
| Feature | Benefit |
|---|---|
| 14 reportable parameters | Comprehensive routine urinalysis panel |
| Qualitative & semi-quantitative output | Supports clinical interpretation |
| Single-strip multi-analyte testing | Efficient specimen handling |
High-Brightness LED Optical System – Four-Wavelength Reflectance Photometry
The analyzer utilizes a high-brightness LED light source with reflectance photometry at 525 nm, 572 nm, 610 nm, and 660 nm, detecting color changes on reagent strips to calculate semi-quantitative concentrations. The LED light source offers long service life and stable illumination for consistent colorimetric readings.
| Feature | Benefit |
|---|---|
| High-brightness LED | Stable illumination with long service life |
| 4-wavelength reflectance photometry | Reliable colorimetric detection |
| 525/572/610/660 nm detection | Broad reagent strip compatibility |
Touchscreen Operation & High-Brightness Display
The analyzer features a high-brightness LCD display for clear result visibility, with an optional 8-inch touchscreen available for direct touch input and intuitive menu navigation. Intelligent key operation supports simple and convenient workflow for laboratory staff.
| Feature | Benefit |
|---|---|
| Optional 8-inch touchscreen | Direct touch operation for efficient workflow |
| High-brightness LCD display | Clear visibility of results and menus |
| Intelligent key operation | Simple, user-friendly navigation |
Extensive Data Storage – Up to 100,000 Results
On-board memory accommodates up to 100,000 patient results in the standard configuration, supporting extended retrospective review, quality control tracking, and patient data management. Dedicated QC result storage is also provided for routine quality control workflows.
| Feature | Benefit |
|---|---|
| 100,000-result storage | Extended on-board data retention |
| QC result storage | Supports routine quality control workflows |
| Retrospective review | Efficient data retrieval and review |
Connectivity – RS-232, Parallel Port & LIS/HIS Integration
The system features RS-232 serial and parallel ports for connection to laboratory information systems and external printers, alongside a built-in high-speed thermal printer (55–57 mm paper) for immediate result documentation.
| Feature | Benefit |
|---|---|
| RS-232 & parallel ports | LIS/HIS connectivity and external printer support |
| Built-in thermal printer | Immediate hard-copy results |
| External printer support | Flexibility for different documentation needs |
Automated Waste Collection & User-Friendly Design
An integrated waste tray automatically collects used reagent strips, supporting a clean and efficient workflow. User-adjustable flag thresholds for abnormal results and software-adjustable sensitivity per test item provide flexibility across different clinical requirements.
| Feature | Benefit |
|---|---|
| Automated waste strip collection | Cleaner workflow with reduced manual handling |
| Adjustable abnormal flags | Customizable result alerting |
| Adjustable item sensitivity | Flexibility across clinical requirements |
Reagent Strip Compatibility – 8A through 14A
The analyzer is compatible with 8A, 10A, 11A, 12A, 13A, and 14A reagent strip formats, providing flexibility in menu configuration and cost management.
| Feature | Benefit |
|---|---|
| 8A–14A strip compatibility | Flexible menu and cost configuration |
| Multiple parameter combinations | Adaptable to different clinical needs |
Compact Footprint – 380 × 380 × 275 mm, 6.5 kg
With dimensions of 380 × 380 × 275 mm and a weight of 6.5 kg, the analyzer occupies minimal bench space and can be placed in satellite laboratories, high-volume testing centers, and space-constrained clinical environments.
| Feature | Benefit |
|---|---|
| 6.5 kg weight | Manageable and easy to relocate |
| 380 × 380 × 275 mm | Space-efficient benchtop installation |
| Compact high-throughput platform | High-volume testing in a small footprint |
Urine Analyzer Strip Pricing (EXW US Dollar)
The following reagent strip configurations are available for the GHM HT-115A US platform. All strips are supplied in 100 Tests/Bottle configurations.
14-Parameter Strip
| Product Description | Parameters Included | Packing | EXW Price (USD/Bottle) |
|---|---|---|---|
| URS-14 Urine Analyzer Strip | VC, LEU, GLU, MALB, BIL, pH, BLD, SG, KET, PRO, NIT, URO, CR, CA | 100 Tests/Bottle | $11.20 |
11-Parameter Strip
| Product Description | Parameters Included | Packing | EXW Price (USD/Bottle) |
|---|---|---|---|
| URS-11 Urine Analyzer Strip | URO, BLD, BIL, KET, LEU, GLU, PRO, pH, NIT, SG, VC | 100 Tests/Bottle | $8.80 |
10-Parameter Strips
| Product Description | Parameters Included | Packing | EXW Price (USD/Bottle) |
|---|---|---|---|
| URS-10C Urine Analyzer Strip | LEU, NIT, URO, PRO, pH, BLD, KET, BIL, GLU, VC | 100 Tests/Bottle | $8.00 |
| URS-10S Urine Analyzer Strip | LEU, NIT, URO, PRO, pH, BLD, SG, KET, BIL, GLU | 100 Tests/Bottle | $8.00 |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM HT-115A US |
| Product Type | Semi-Automated Urine Analyzer |
| Intended Use | Qualitative or semi-quantitative determination of urine parameters in human urine specimens for routine clinical urinalysis; professional in vitro diagnostic use |
| Testing Principle | Reflectance photometry with high-brightness LED light source |
| Reportable Parameters | Up to 14 (LEU, NIT, URO, PRO, pH, BLD, SG, KET, BIL, GLU, VC, CR, CA, MALB) |
| Throughput | 514 tests/hour |
| Detection Wavelengths | 525 nm, 572 nm, 610 nm, 660 nm |
| Compatible Strip Codes | 8A, 10A, 11A, 12A, 13A, 14A |
| Display | High-brightness LCD; optional 8-inch touchscreen |
| Data Storage | Up to 100,000 patient results; QC result storage |
| Communication | RS-232 serial port; parallel port; LIS/HIS compatible |
| Printer | Built-in high-speed thermal printer (55–57 mm paper); external printer support |
| Waste Handling | Integrated automated waste strip collection tray |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 65 VA |
| Dimensions | 380 mm × 380 mm × 275 mm |
| Weight | 6.5 kg |
| Storage Conditions | −40°C to 55°C; 10%–95% RH (non-condensing); 70–106 kPa |
| Applicable Settings | Hospital laboratories, polyclinics, high-volume testing centers |
| Regulatory Status | Manufactured under EN ISO 13485 certified quality management system |
Why Clinical Laboratories Choose Global Healthcare Medical
| Consideration | GHM HT-115A US |
|---|---|
| High throughput | 514 tests/hour for high-volume routine urinalysis |
| 14-parameter testing | Comprehensive screening panel from a single strip |
| High-brightness LED optics | Stable illumination with 4-wavelength detection |
| Optional touchscreen | 8-inch touch interface for efficient operation |
| 100,000-result storage | Extended on-board data retention |
| LIS/HIS connectivity | RS-232 and parallel ports for seamless integration |
| Automated waste collection | Cleaner workflow with reduced manual handling |
| 8A–14A strip compatibility | Flexible menu and cost configuration |
| Compact footprint | 380 × 380 × 275 mm, 6.5 kg |
| ISO 13485 certified | Quality management system compliance |
About Global Healthcare Medical
Global Healthcare Medical connects hospital laboratories, polyclinics, and high-volume testing centers with high-performance diagnostic systems designed for reliable operation in demanding clinical environments. The GHM HT-115A US is part of our professional urinalysis analyzer line, developed to support rapid, high-throughput, and reliable routine urine testing.