WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM Lipid US Lipid Testing System – Quantitative, 2-Minute, Whole Blood/Serum/Plasma
GHM Lipid US Lipid Testing System – Quantitative, 2-Minute, Whole Blood/Serum/Plasma
SKU: GHM Lipid US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM Lipid US Lipid Testing System is a portable, hand-held testing system designed for the quantitative determination of Total Cholesterol (TC), High-Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), the calculated ratio of TC/HDL, and Low-Density Lipoprotein Cholesterol (LDL) in capillary and venous human whole blood, serum, or plasma samples. The measurement of lipid parameters is used as an aid in the management of metabolic disorders involving lipids and lipoproteins.
The GHM Lipid US is a hand-held device that provides fast, reliable lipid panel results in just 2 minutes using a small blood volume (25 μL for lipid panel, 10 μL for individual tests). The system utilizes a reflectance photometer method and supports flexible testing configurations, including individual TC, TG, and HDL tests, as well as a comprehensive 3-1 lipid panel (TC, TG, HDL, LDL, and TC/HDL ratio).
The system is designed for professional use in hospitals, clinics, and pharmacies. The analyzer operates with a small sample volume and provides fast, reliable results with simple operation.
This product is for in vitro diagnostic use only. For professional use only.
Key Features & Benefits
Quantitative Lipid Panel Measurement – Aid in Lipid Disorder Management
The GHM Lipid US delivers quantitative lipid results, providing measurable concentration values that can be used as an aid in the management of metabolic disorders involving lipids and lipoproteins. Lipid testing is essential for assessing cardiovascular risk and monitoring the effectiveness of lipid-lowering interventions.
| Feature | Benefit |
|---|---|
| Quantitative result | Provides measurable lipid concentration values |
| Specimen types | Whole blood (capillary, venous), serum, plasma |
| Intended use | Aid in management of lipid and lipoprotein metabolic disorders |
| Test time | 2 minutes |
| Test items | Individual: TC, TG, HDL; Panel: TC, TG, HDL, LDL, TC/HDL ratio |
| Clinical utility | Supports cardiovascular risk assessment and lipid monitoring |
Reflectance Photometer Method – Reliable Measurement Principle
The GHM Lipid US utilizes a reflectance photometer method. The system measures the degree of light reflectance from the test strip, which correlates with the concentration of the target lipid analyte in the sample. The analyzer processes the signal to display the quantitative lipid concentration.
| Feature | Benefit |
|---|---|
| Reflectance photometer | Reliable quantitative measurement principle |
| Small blood volume | Lipid panel: 25 μL; Individual tests: 10 μL |
| Fast results | 2 minutes per test |
| Multi-parameter testing | Supports individual and panel configurations |
Comprehensive Lipid Panel – Broad Testing Coverage
The GHM Lipid US supports detection of a comprehensive lipid panel, providing broad coverage for clinical lipid testing needs.
| Test Configuration | Test Items |
|---|---|
| Individual Tests | Total Cholesterol (TC), Triglycerides (TG), High-Density Lipoprotein Cholesterol (HDL) |
| 3-1 Lipid Panel | TC, TG, HDL, LDL (calculated), TC/HDL ratio (calculated) |
Measurement Ranges:
| Analyte | Measurement Range |
|---|---|
| Total Cholesterol (TC) | 100 – 500 mg/dL (2.59 – 12.93 mmol/L) |
| HDL Cholesterol | 15 – 120 mg/dL (0.39 – 3.10 mmol/L) |
| Triglycerides (TG) | 45 – 650 mg/dL (0.51 – 7.34 mmol/L) |
Reference Values:
| Analyte | Reference Value |
|---|---|
| TC | <200 mg/dL (<5.2 mmol/L) |
| HDL | ≥40 mg/dL (≥1.0 mmol/L) |
| TG | <150 mg/dL (<1.7 mmol/L) |
| LDL | <130 mg/dL (<3.4 mmol/L) |
Advanced System Design – Portable and User-Friendly
The GHM Lipid US is a compact, hand-held device designed for convenient point-of-care use. The system features a memory capacity of 200 records with date/time and Mini USB connectivity.
| Feature | Benefit |
|---|---|
| Compact design | Hand-held, portable format |
| Memory capacity | 200 records with date/time |
| Connectivity | Mini USB |
| Units of measurement | mg/dL, mmol/L |
| Test device shelf life | 18 months |
Wide Storage Temperature – No Cold Chain Required
The test device is designed for convenient storage and transport, with a storage temperature range of 2 ~ 30°C, eliminating the need for cold chain logistics.
| Specification | Detail |
|---|---|
| Meter storage temperature | 0 ~ 50°C |
| Test device storage temperature | 2 ~ 30°C |
| Operating temperature | 15 ~ 40°C |
| Test device shelf life | 18 months |
Simple Operation – Professional Point-of-Care Testing
The test procedure involves three simple steps: collect the blood sample, apply the sample to the test device, and insert the device into the analyzer.
| Step | Action |
|---|---|
| 1 | Collect the capillary or venous whole blood sample |
| 2 | Apply the sample to the test device |
| 3 | Insert the test device into the analyzer for measurement |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM Lipid US |
| Product Type | Lipid Testing System |
| Specimen | Whole blood (capillary, venous), Serum, Plasma |
| Sample Volume | Lipid panel: 25 μL; Individual tests: 10 μL |
| Test Time | 2 minutes |
| Test Items | TC, TG, HDL, LDL (calculated), TC/HDL ratio (calculated) |
| Methodology | Reflectance photometer |
| Measurement Range (TC) | 100 – 500 mg/dL (2.59 – 12.93 mmol/L) |
| Measurement Range (HDL) | 15 – 120 mg/dL (0.39 – 3.10 mmol/L) |
| Measurement Range (TG) | 45 – 650 mg/dL (0.51 – 7.34 mmol/L) |
| Units of Measurement | mg/dL, mmol/L |
| Memory | 200 records with date/time |
| Connectivity | Mini USB |
| Meter Storage Temperature | 0 ~ 50°C |
| Test Device Storage Temperature | 2 ~ 30°C |
| Operating Temperature | 15 ~ 40°C |
| Test Device Shelf Life | 18 months |
| Intended Use | In vitro diagnostic use; professional use only |
| Package Options | Analyzer system, test devices |
Why Clinical Laboratories Choose Global Healthcare Medical
| Consideration | GHM Lipid US |
|---|---|
| Quantitative results | Measurable lipid concentration values |
| Flexible specimen types | Whole blood, serum, or plasma |
| Fast test time | 2 minutes per test |
| Small blood volume | 25 μL for panel, 10 μL for individual tests |
| Comprehensive lipid panel | TC, TG, HDL, LDL, and TC/HDL ratio |
| Portable design | Hand-held, compact format |
| Memory capacity | 200 records with date/time |
| Convenient storage | 2 ~ 30°C test device storage, no cold chain required |
| Simple operation | Three-step test procedure |
| Multiple test configurations | Individual tests and 3-1 lipid panel |