GHM MDK-310 US Fully Auto Glycated Hemoglobin (HbA1c) Analyzer – 10-Position Ion-Exchange HPLC System with 75-Second Fast Mode, Continuous Sample Loading and Dual IFCC/NGSP Reporting
GHM MDK-310 US Fully Auto Glycated Hemoglobin (HbA1c) Analyzer – 10-Position Ion-Exchange HPLC System with 75-Second Fast Mode, Continuous Sample Loading and Dual IFCC/NGSP Reporting
SKU: GHM MDK-310 US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM MDK-310 US is a fully automated benchtop analyzer for the separation and quantification of glycated hemoglobin (HbA1c) and hemoglobin fractions by high-performance ion-exchange liquid chromatography (HPLC), built around a 75-second analytical cycle and a continuously fed 10-position sample disk. It is the throughput-oriented configuration of the GHM HPLC platform: the same ion-exchange chemistry and the same three-buffer reagent set, with a shorter cycle time and automatic continuous rack loading that keep the instrument working through a queue of samples rather than waiting for a batch to be assembled by hand.
The instrument performs the complete analytical sequence without operator intervention between loading and result output: the sample is identified by barcode, the primary tube cap is pierced automatically, 5 µL of whole blood is aspirated, haemolysed in-line at a 5 µL : 1,500 µL ratio, injected onto a cation-exchange column, eluted under a programmed gradient and detected at 415 nm — the absorbance maximum of the haem group. Results print on the integrated thermal printer, are written to on-board storage, and can be routed to a laboratory information system over USB.
Separation is charge-based cation exchange, not an antibody or enzymatic reaction. Hemoglobin species differ in net surface charge according to globin composition and post-translational modification; HbA1c carries additional negative charge at the N-terminal valine of the β-chain through irreversible glucose adduction and therefore elutes at a reproducible position relative to the unmodified HbA0 peak. The instrument integrates peak area across defined elution windows and reports percentage composition for each fraction. Because the result is a peak-area ratio taken directly from the chromatogram, it does not depend on reagent-lot immunoreactivity, and it is traceable to column separation performance and pump flow stability.
Three modes are selectable in software from the same installed reagent set, with no reagent change, column change or re-plumbing. Fast mode returns a HbA1c result in 75 seconds — 48 samples per hour; Variant mode (100 seconds) opens the integration window to report HbA1a, HbA1b, labile A1c (LA1c), stable A1c, HbF, HbA2 and the variant fractions HbS, HbD, HbE and HbJ; A2/F mode (240 seconds) extends the run to resolve the A2 and F regions for HbA2 and HbF quantification. All results are reported in both IFCC (mmol/mol) and NGSP (%) units from a single injection.
Consumables are the 4,000-test chromatographic column, the 500-test in-line pre-sieve (nine supplied with the instrument) and buffer packs in 100, 200, 500, 1,000 and 2,000-test sizes, with every pack price listed in the pricing section below.
Intended Use: For professional laboratory use. The instrument is intended for operation by qualified laboratory personnel within a controlled laboratory environment. It is not intended for self-testing, home use, or operation by untrained personnel. Results should be interpreted by qualified laboratory professionals in accordance with the laboratory's own validated procedures and applicable local regulations.
Important: The analyzer is supplied as a main unit without the chromatographic column; the column is ordered separately as a consumable (see pricing).
Key Features & Benefits
75-Second Cycle, 48 Samples per Hour
The 75-second Fast cycle is a complete analytical cycle, not a partial one: aspiration, in-line haemolysis, injection, gradient separation, 415 nm detection, peak integration, printing and data storage all occur inside it. At that cycle time the instrument delivers 48 HbA1c results per hour, which changes how a 10-position disk behaves in practice — a full disk is consumed in roughly twelve and a half minutes, so the disk is a flow buffer rather than a batch container. For a laboratory running morning peaks, the difference between a 90-second and a 75-second cycle is the difference between 40 and 48 results per hour, or roughly 60 additional results across a seven-hour working day.
|
Feature |
Benefit |
|
75-second complete cycle |
Aspiration to printed result inside one cycle |
|
48 samples per hour |
Higher morning-peak capacity than a 90-second cycle |
|
Full disk consumed in ~12.5 minutes |
Disk functions as a flow buffer, not a batch |
|
~60 extra results per 7-hour day |
Measurable capacity gain at unchanged staffing |
Continuous Automatic Sample Loading
Loading is continuous and automatic: as positions on the 10-place disk free up, further primary tubes or sample cups can be added and the instrument picks them up without a run being restarted or a batch being completed. Combined with a 75-second cycle, this removes the idle time that appears whenever a manual batch finishes before the next batch is assembled — the analyzer is fed sample by sample rather than batch by batch. The disk accepts primary blood tubes and sample cups interchangeably in the same run, so a laboratory can mix tube types without reconfiguring anything.
|
Feature |
Benefit |
|
Continuous automatic loading |
Samples added while the run continues |
|
No batch assembly wait |
Instrument does not idle between batches |
|
10-position disk |
Steady queue at a 75-second cycle |
|
Tubes and cups in the same run |
Mixed collection formats without reconfiguration |
Three Modes at 75 / 100 / 240 Seconds
Fast, Variant and A2/F are software states of one hardware and reagent configuration. Fast (75 s) covers routine HbA1c; Variant (100 s) adds the extended fraction set including HbA1a, HbA1b, LA1c, stable A1c, HbF and the variant windows HbS, HbD, HbE and HbJ; A2/F (240 s) resolves the A2 and F regions for HbA2 and HbF quantification. Because all three run on the same buffers and the same column, a laboratory can move from routine throughput to extended profiling for an individual sample without interrupting reagent supply, swapping a column or recalibrating. The 240-second A2/F cycle is also short enough that extended profiling does not have to be deferred to a separate shift.
|
Feature |
Benefit |
|
Fast 75 s / Variant 100 s / A2/F 240 s |
One platform, three cycle budgets |
|
Same buffers and column in all modes |
No swap, no re-plumbing, no recalibration |
|
Variant windows S, D, E, J |
Unexpected peaks visible rather than suppressed |
|
240 s A2/F cycle |
Extended profiling fits inside the working day |
Wide Measuring Range and Full Fraction Panel
The calibrated measuring range is HbA1c 3–25% (9–250 mmol/mol), HbF 0.45–45% and HbA2 0–15%. The 25% upper HbA1c boundary sits well above the 18–20% ceiling common on compact HPLC systems, so samples at the extreme high end of the distribution stay inside the calibration envelope instead of being flagged above-range and diluted by hand. Each run reports the full fraction set — HbA1a, HbA1b, LA1c, stable A1c, HbF, HbA2 and the variant fractions — so one injection yields both a quantitative HbA1c value and a chromatogram that can be reviewed for unexpected peaks.
|
Feature |
Benefit |
|
HbA1c 3–25% |
Wider upper boundary than typical compact systems |
|
HbF 0.45–45% / HbA2 0–15% |
Extended coverage of the F and A2 regions |
|
Full fraction panel |
Quantitative result plus qualitative review in one run |
|
Variant windows reported |
Atypical peaks are documented, not hidden |
CV ≤ 2% with Dual IFCC / NGSP Reporting
Repeatability is specified at CV ≤ 2%, and every result is reported in both IFCC (mmol/mol) and NGSP (%) units from the same chromatogram — no conversion sheet, no second run. Dual-unit output matters wherever results are exchanged with collaborators or publications that use a different convention, because one analytical measurement is presented in both reference frames at once. Chromatograms are retained on board (50,000 results, or 7,500 results with full curves) and can be exported through the independent PC software for archival reporting, curve review and trend analysis.
|
Feature |
Benefit |
|
CV ≤ 2% |
Consistent replicate performance across the range |
|
IFCC and NGSP together |
One run, two reporting conventions |
|
50,000 stored results |
Long retention without external archiving |
|
7,500 results with curves |
Chromatograms kept for retrospective review |
|
Independent PC software |
Curve review, report generation, data export |
Long-Life Consumables and Five Buffer Pack Sizes
The column is rated for 4,000 tests and the pre-sieve for 500 tests (nine supplied), so scheduled maintenance follows test count rather than the calendar. Buffer packs come in 100, 200, 500, 1,000 and 2,000-test configurations, letting a laboratory match standing inventory to its real monthly workload instead of committing to one oversized pack. Reagents carry a two-year shelf life and remain usable for three months after opening; an opened column is rated for 4,000 tests within two years of opening, so a low-volume laboratory can run a column to its rated capacity rather than discard it unused.
|
Feature |
Benefit |
|
4,000-test column |
Replacement roughly once per 4,000 results |
|
Five buffer pack sizes (100–2,000 tests) |
Inventory sized to actual monthly volume |
|
500-test pre-sieve, 9 supplied |
Filter changes known in advance |
|
2-year shelf life / 3 months in use |
Less write-off, workable open-pack window |
|
Column rated 4,000 tests over 2 years |
Full utilisation at low test volumes |
Compact 20 kg Chassis with Standard Laboratory Integration
The instrument measures 310 × 470 × 500 mm and weighs 20 kg, so it takes a single bench position rather than a dedicated workstation — notable for a unit delivering 48 results per hour. It runs from 110–220 V, 50–60 Hz across a 5–38 °C, 30–70% RH envelope, connects through USB with LIS/HIS support, and is operated from a 10.4-inch TFT colour LCD touch screen with barcode-scanner or touch-keypad input. Reports issue on the built-in thermal printer or an external printer, and report layouts can be customised to the site's own template.
|
Feature |
Benefit |
|
310 × 470 × 500 mm, 20 kg |
Single bench position at 48 results/hour |
|
110–220 V, 50–60 Hz |
Dual-range supply, no site configuration |
|
5–38 °C / 30–70% RH |
Tolerant of normal ambient variation |
|
USB with LIS/HIS support |
Direct laboratory information system integration |
|
10.4-inch colour touch screen |
Chromatogram and fraction table on one screen |
|
Customisable report layout |
Output matched to the site's template |
System Contents & Pricing (EXW, USD)
Analyzer configuration
|
Item |
Detail |
|
Main unit |
Fully automated HPLC HbA1c analyzer, 10-position continuous-loading disk, column not included |
|
Supplied with unit |
Power cord, thermal paper roll, user manual, 9 × pre-sieve/filter |
|
Column |
Ordered separately — see consumables below |
Analyzer pricing is quoted per configuration and destination. Request a quotation for the current EXW price of the main unit.
Reagents, consumables and accessories
|
Product Description |
Pack Size |
Price/Pack (USD) |
|
Buffer ABCL Set — Buffer A 750 mL ×1, Buffer B 750 mL ×1, Buffer C 750 mL ×1, Hemolysin 750 mL ×1 |
100 tests |
$105.00 |
|
Buffer ABCL Set — Buffer A 750 mL ×1, Buffer B 750 mL ×1, Buffer C 750 mL ×1, Hemolysin 750 mL ×1 |
200 tests |
$105.00 |
|
Buffer ABCL Set — Buffer A 750 mL ×2, Buffer B 750 mL ×3, Buffer C 750 mL ×2, Hemolysin 750 mL ×3 |
500 tests |
$250.50 |
|
Buffer ABCL Set — Buffer A 750 mL ×4, Buffer B 750 mL ×6, Buffer C 750 mL ×4, Hemolysin 750 mL ×6 |
1,000 tests |
$501.00 |
|
Buffer ABCL Set — Buffer A 750 mL ×8, Buffer B 750 mL ×12, Buffer C 750 mL ×8, Hemolysin 750 mL ×12 |
2,000 tests |
$1,002.00 |
|
Chromatographic Column |
4,000 tests |
$675.00 |
|
Quality Control Set — low value + high value |
2 levels |
$12.00 |
|
Calibrator Set — low value + high value |
2 levels |
$12.00 |
|
Pre-Sieve / Filter (9 supplied with instrument; replace every 500 tests) |
Each |
$12.00 |
Reagent storage: two-year shelf life from manufacture; three months in use after opening. An opened column is rated for 4,000 tests within two years of opening.
Pricing terms: EXW, USD, excluding freight, insurance, duties and local taxes. Prices are per pack as listed.
Product Specifications
|
Specification |
Detail |
|
Model / SKU |
GHM MDK-310 US |
|
Product Type |
Fully automated glycated hemoglobin (HbA1c) analyzer |
|
Methodology |
High-performance ion-exchange liquid chromatography (HPLC) |
|
Detection |
415 nm LED photometer, rated emitter life 20,000 hours |
|
Separation |
Cation-exchange column, three-buffer programmed gradient (A / B / C) |
|
Pump |
High-stability HPLC pump, constant-flow gradient delivery |
|
Test Modes & Speed |
Fast 75 s/test; Variant 100 s/test; A2/F 240 s/test |
|
Throughput |
48 samples/hour in Fast mode |
|
Measuring Range |
HbA1c 3–25% (9–250 mmol/mol); HbF 0.45–45%; HbA2 0–15% |
|
Precision |
CV ≤ 2% |
|
Reported Parameters |
HbA1c; HbA1a, HbA1b, LA1c, stable A1c, HbF, HbA2; variants HbS, HbD, HbE, HbJ |
|
Reporting Units |
IFCC (mmol/mol) and NGSP (%) from the same run |
|
Sample Types |
Venous whole blood, finger-peripheral blood, haemolysed blood |
|
Sample Volume |
5 µL whole blood; haemolysate at 5 µL : 1,500 µL ratio |
|
Sample Capacity |
10 positions per disk; primary tubes and sample cups, interchangeable |
|
Sample Handling |
Barcode identification, automatic cap piercing, continuous automatic loading, in-line haemolysis |
|
Column Capacity |
4,000 tests |
|
Pre-Sieve Capacity |
500 tests (9 supplied) |
|
Display |
10.4-inch TFT colour LCD touch screen |
|
Input |
Built-in barcode scanner or touch keypad |
|
Data Storage |
50,000 results, or 7,500 results with full chromatogram curves |
|
Data Transfer |
USB; LIS/HIS support; independent PC software |
|
Printer |
Integrated thermal printer; external printer supported |
|
Working Conditions |
5–38 °C, 30–70% RH |
|
Power Supply |
110–220 V, 50–60 Hz |
|
Dimensions |
310 × 470 × 500 mm |
|
Weight |
20 kg |
|
Intended Use |
Quantification of glycated hemoglobin and hemoglobin fractions in whole blood; for professional laboratory use; not for self-testing or home use |
|
Regulatory Status |
Manufactured under an EN ISO 13485 certified quality management system; market clearance varies by country |
Why Laboratories Choose Global Healthcare Medical
|
Consideration |
GHM MDK-310 US |
|
75-second Fast cycle |
Complete aspiration-to-print cycle |
|
48 samples per hour |
Higher capacity than a 90-second platform |
|
Continuous automatic loading |
Samples added while the run continues |
|
Three modes, one reagent set |
75 / 100 / 240 s without reagent change |
|
Automatic cap piercing |
Primary tubes loaded directly, no decapping |
|
5 µL whole blood |
Low sample volume, finger-peripheral compatible |
|
HbA1c range 3–25% |
Wider upper boundary than typical compact systems |
|
Dual IFCC / NGSP reporting |
Both conventions from one chromatogram |
|
CV ≤ 2% |
Consistent replicate performance |
|
4,000-test column |
Infrequent column replacement |
|
20 kg, single bench position |
Full throughput without a dedicated workstation |
|
LIS/HIS connectivity |
Direct laboratory information system integration |
About Global Healthcare Medical
Global Healthcare Medical supplies clinical laboratories, reference laboratories, and analytical service facilities with laboratory reagents and benchtop analytical systems engineered for dependable operation in demanding healthcare environments. The GHM MDK-310 US sits within our professional HPLC analyzer portfolio alongside the GHM MDK-300 US, sharing the same reagent set, column and consumable range so that a laboratory can standardise on one consumable inventory across both configurations.
Our focus is on verifiable analytical performance, complete technical documentation, and responsive support for professional laboratory operations.