WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM Respiratory US Respiratory Virus Rapid Test (FIA) – Qualitative, 15-Minute, Nasopharyngeal Swab
GHM Respiratory US Respiratory Virus Rapid Test (FIA) – Qualitative, 15-Minute, Nasopharyngeal Swab
SKU: GHM Respiratory US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM Respiratory US Respiratory Virus Rapid Test (FIA) is a fluorescence immunoassay (FIA) designed for the qualitative and differential detection of multiple respiratory pathogens from a single nasopharyngeal swab sample. The test is used as an aid in the diagnosis of respiratory tract infections and supports the rapid differentiation between viral and bacterial respiratory pathogens.
The GHM Respiratory US is intended for use with the FIA Analyzer (VIM01), a compact benchtop analyzer that utilizes fluorescence immunochromatography technology. The analyzer features auto calibration, barcode identification, and a built-in memory capacity of 50,000 results. The analyzer delivers reliable results in 10 ± 5 seconds after the test device is inserted.
The system is designed for professional use in clinical laboratories, hospitals, and clinics. The FIA analyzer operates with a small sample volume and provides fast, reliable results with simple operation.
This product is for in vitro diagnostic use only. For professional use only.
Key Features & Benefits
Multiplex Respiratory Pathogen Detection – Comprehensive Differential Assessment
The GHM Respiratory US delivers qualitative results for multiple respiratory pathogens from a single nasopharyngeal swab specimen. This multiplex panel approach enables simultaneous detection and differentiation of viral and bacterial respiratory pathogens, supporting timely clinical decision-making and antimicrobial stewardship. Antimicrobial stewardship guidelines advocate rapid testing for broad panels of respiratory viruses as an important intervention to reduce the use of inappropriate antibiotics.
| Feature | Benefit |
|---|---|
| Multiplex panel | Simultaneous detection of multiple respiratory pathogens |
| Single specimen | One nasopharyngeal swab for all test items |
| Intended use | Aid in diagnosis of respiratory tract infections |
| Test time | 15 minutes |
| Clinical utility | Supports differentiation between viral and bacterial respiratory infections |
Comprehensive Test Menu – Broad Pathogen Coverage
The GHM Respiratory US supports detection of a comprehensive panel of respiratory pathogens, providing broad coverage for clinical respiratory testing needs.
| Pathogen Category | Test Items |
|---|---|
| Viruses | SARS-CoV-2, Influenza A, Influenza B, Respiratory Syncytial Virus (RSV), Adenovirus (ADV), Human Metapneumovirus (hMPV), Human Rhinovirus (RhV), Human Parainfluenza Virus (hPIV) |
| Bacteria | Mycoplasma pneumoniae (MP), Streptococcus pneumoniae (SP) |
Multiple panel configurations available. Contact Global Healthcare Medical for the complete test menu and panel customization options.
Sandwich Immunodetection Method – Fluorescence Immunoassay Principle
The GHM Respiratory US uses a sandwich immunodetection method. Detector antibodies in buffer bind to target respiratory pathogen antigens in the sample, forming antigen-antibody complexes, and migrate onto a nitrocellulose matrix to be captured by immobilized antibodies on the test strip. If target antigens are present, they are captured on the surface of fluorescent microbeads coated with pathogen-specific antibodies. Microbeads that carry bound antigen are then captured by secondary antibodies at specific locations on the test strip, where they are detected by the analyzer. If no target antigens are present, the microbeads are not captured and are not detected.
| Feature | Benefit |
|---|---|
| Sandwich immunodetection | Reliable qualitative measurement principle |
| Fluorescence signal | Clear positive/negative determination |
| Test strip technology | Pathogen-specific antibodies at test lines; control line verification |
| Objective results | Results interpreted automatically by analyzer |
FIA Analyzer – Advanced Technical Platform
The GHM Respiratory US is used with the FIA Analyzer (VIM01), a compact fluorescence immunoassay analyzer featuring auto calibration, barcode identification, and a large memory capacity.
| Feature | Benefit |
|---|---|
| Auto calibration | Reduces manual calibration steps |
| Barcode identification | 2D barcode scanning for test device identification |
| Code chip coding | Automatic parameter recognition |
| Memory capacity | 50,000 results storage |
| Connectivity | Direct LIS/HIS connection |
| Display | 3.5-inch LCD screen |
| Dimensions | 173 × 210 × 75.8 mm |
| Weight | 1.5 kg |
| Printer | Built-in printer |
| Multi-parameter detection | Analyzer can detect 30+ parameters |
Wide Storage Temperature – No Cold Chain Required
The test kit is designed for convenient storage and transport, with a storage temperature range of 2 ~ 30°C, eliminating the need for cold chain logistics.
| Specification | Detail |
|---|---|
| Kit storage temperature | 2 ~ 30°C |
| Operating temperature | 18 ~ 25°C |
| Relative humidity | 20 – 90% |
Simple Operation – Professional Laboratory Testing
The test procedure involves three simple steps: collect the nasopharyngeal swab sample, add the processed specimen to the test device, and insert the device into the analyzer.
| Step | Action |
|---|---|
| 1 | Collect the nasopharyngeal swab specimen |
| 2 | Add the processed specimen to the test device |
| 3 | Insert device into the analyzer |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM Respiratory US |
| Product Type | Respiratory Virus Rapid Test (FIA) |
| Specimen | Nasopharyngeal swab |
| Test Time | 15 minutes |
| Measuring Range | Negative / Positive |
| Operating Temperature | 18 ~ 25°C |
| Storage Temperature | 2 ~ 30°C |
| Analyzer Compatibility | FIA Analyzer (VIM01) |
| Analyzer Display | 3.5-inch LCD |
| Analyzer Dimensions | 173 × 210 × 75.8 mm |
| Analyzer Weight | 1.5 kg |
| Analyzer Memory | 50,000 results |
| Analyzer Connectivity | Direct LIS/HIS |
| Analyzer Test Time | 10 ± 5 seconds |
| Analyzer Operation Temperature | 5 ~ 40°C |
| Analyzer Storage Temperature | -10 ~ 40°C |
| Relative Humidity | 20 – 90% |
| Intended Use | In vitro diagnostic use; professional use only |
| Package Options | Kit format |
Why Clinical Laboratories Choose Global Healthcare Medical
| Consideration | GHM Respiratory US |
|---|---|
| Multiplex results | Multiple pathogen detection from one swab |
| Broad pathogen coverage | Viruses and bacteria in a single panel |
| Fast test time | 15 minutes per test |
| Fast analyzer reading | 10 ± 5 seconds per test |
| Auto calibration | Reduces manual steps |
| Large memory | 50,000 results storage |
| LIS/HIS connectivity | Direct data integration |
| Convenient storage | 2 ~ 30°C, no cold chain required |
| Simple operation | Three-step test procedure |
| Multi-parameter platform | Analyzer supports 30+ parameters |