⚡ Complete in 5 Minutes — Staining & Coverslipping Together
The GHM-RF-I is the only instrument you need for both staining and coverslipping. This all-in-one system completes the entire staining and coverslipping process in just 5 minutes — dramatically reducing histology turnaround time.
Why it matters: Get slides to pathologists faster. Eliminate the bottleneck between staining and coverslipping. No more waiting for a separate coverslipper to catch up.
🚀 100 Slides per Hour — 800 Coverslips per Hour
The GHM-RF-I delivers 100 slides per hour for staining and an impressive 200 slides per hour for coverslipping — that's 800 coverslips per hour. High throughput without compromising quality.
Why it matters: Keep pace with even the busiest histology labs. Process batch after batch with consistent speed, no matter how high your volume.
🎛️ One-Button Start — Always Ready
Simplicity is key in a busy lab. The GHM-RF-I features one-button operation — just press start and walk away. The system is always ready for staining, and you can add specimens at any time without interrupting the current run.
Why it matters: No complex programming. No waiting for cycles to finish. Your technicians can load and unload continuously throughout the day.
🧪 Flexible Program Design for Any Protocol
Different stains require different protocols. The GHM-RF-I lets you design and save up to 24 custom programs with up to 54 steps each. Whether it's H&E, special stains, or research protocols, the system adapts to your needs.
Why it matters: One instrument handles all your staining requirements. No dedicated stainer for each stain type. Change protocols in seconds.
🏥 Minimum Footprint — Maximum Efficiency
Dimensions: 920mm × 530mm × 550mm (W×D×H). Weight: 100kg. The GHM-RF-I packs staining and coverslipping into a surprisingly small footprint for a system with this capability.
Why it matters: Fits on standard lab benches and through doorways. Perfect for labs where space is at a premium. Easy to maintain with accessible components.
🔬 24 Stations — 16 Reagent Stations — 4 Heated Stations
The GHM-RF-I features:
-
24 total stations for maximum flexibility
-
16 reagent stations for multiple stain types and buffers
-
4 reagent heating stations with precise temperature control (0°C–60°C, ±1°C accuracy)
-
4 washing stations for thorough rinsing
-
2 drying oven stations to prepare slides for coverslipping
Why it matters: Run complex staining protocols without reconfiguring the instrument. Heat-sensitive stains are handled with ±1°C precision.
🧩 8-Slide Rack Capacity — Batch or Continuous Loading
Each staining rack holds 8 slides, and the input/output drawer accommodates one rack at a time. Load a rack, start the run, and load the next rack while the first is processing.
Why it matters: Perfect for small to medium-volume labs. Process STATs immediately without waiting for a full batch. Scale up by running multiple racks throughout the day.
🎯 Intelligent Coverslipping Features
The integrated coverslipper includes smart features that save time and prevent errors:
| Feature | Benefit |
|---|---|
| Defective coverslip detection | Automatically identifies and rejects damaged or flawed coverslips |
| Empty coverslip detection | Real-time monitoring of coverslip availability |
| Low inventory pre-alert | Warns before coverslips run out — no unexpected stops |
| 200 coverslip storage capacity | Run longer between refills |
Why it matters: No ruined slides from bad coverslips. No mid-run surprises. Your coverslipper runs smoothly from morning to evening.
🖥️ 7-Inch Touchscreen with Voice Reminders
The GHM-RF-I features a 7-inch color touchscreen with an intuitive interface. Voice reminders alert technicians when racks are ready, when reagents are low, or when attention is needed.
Why it matters: Technicians can multitask without constantly watching the screen. Voice alerts mean you never miss a cycle completion or maintenance reminder.
🌡️ Precise Temperature Control — ±1°C Accuracy
Reagent heating stations maintain temperature with ±1°C accuracy from 0°C to 60°C. Consistent, reproducible staining results run after run.
Why it matters: Heat-sensitive stains (like special stains and immunohistochemistry) require precise temperature control. The GHM-RF-I delivers scientific-grade accuracy.
🔌 CE-IVDR Certified — Ready for Global Labs
The GHM-RF-I is CE-IVDR certified, meeting the latest European regulatory standards for in vitro diagnostic medical devices.
Why it matters: Compliance you can trust. Deploy with confidence in regulated diagnostic labs worldwide.
🌍 Global Power Ready — 100–240V, 50/60Hz
Operates on 100–240V AC, 50/60Hz with interchangeable power sockets (Types A, C, D, E/F, G, I, J, L, M). Rated power: just 150VA.
Why it matters: Same instrument works anywhere in the world. No transformer needed. Low power consumption saves energy costs.
📦 Complete Staining & Coverslipping Solution — What's Included
-
GHM-RF-I Stainer and Coverslipper unit
-
Staining racks (8-slide capacity each)
-
Reagent containers (160ml each, 16 included)
-
Coverslip magazine (holds 200 coverslips)
-
Output racks (holds 16 slides)
-
Power cord (regional type supplied)
-
Quick start guide and protocol templates
-
1-year warranty with technical support
📊 Quick Specs
| Feature | Specification |
|---|---|
| Staining throughput | 100 slides per hour |
| Coverslipping throughput | 200 slides per hour (800 coverslips/hour) |
| Complete cycle time | 5 minutes (staining + coverslipping) |
| Total stations | 24 |
| Reagent stations | 16 (160ml each) |
| Heated stations | 4 (0°C–60°C, ±1°C accuracy) |
| Washing stations | 4 |
| Drying oven stations | 2 |
| Rack capacity | 8 slides per rack |
| Program storage | 24 programs, up to 54 steps each |
| Coverslip storage | 200 coverslips (24×50mm) |
| Coverslip detection | Defective, empty, and low inventory |
| Dimensions | 920 × 530 × 550 mm |
| Weight | 100 kg |
| Screen | 7-inch touchscreen with voice reminders |
| Power | 100–240V, 50/60Hz, 150VA |
| Certification | CE-IVDR |
📈 Compare Models: KF-RF Series
| Feature | RF‑I | RF‑II | RF‑III | RF‑V |
|---|---|---|---|---|
| Staining throughput | 100/hr | 200/hr | 300/hr | 600/hr |
| Coverslipping throughput | 200/hr | 300/hr | 400/hr | 600/hr |
| Rack slides capacity | 8 | 30 | 30×2 | 30×10 |
| Reagent stations | 16 | 20 | 21–23 | 23–27 |
| Heated stations | 4 | 4 | 4 | 2–6 |
| Dimensions (mm) | 920×530×550 | 1270×590×760 | 1528×625×705 | 1903×715×695 |
| Weight | 100kg | 130kg | 165kg | 205kg |
| Best for | Small to mid-volume labs | Mid-volume labs | High-volume labs | Industrial-scale labs |
Which one is right for you?
-
Choose RF-I if you process up to 100 slides/hour and need a compact, affordable all-in-one
-
Choose RF-II if you need 200 slides/hour with larger reagent volumes (450ml)
-
Choose RF-III for 300+ slides/hour with expanded capacity
-
Choose RF-V for high-throughput industrial or core lab environments
💡 Perfect For
✅ Hospital pathology labs — Routine H&E staining and coverslipping
✅ Reference laboratories — High-volume slide processing
✅ Research institutions — Flexible protocols for special stains
✅ Teaching hospitals — Reliable, easy-to-operate system
✅ Small to mid-volume labs — Entry-level automation without compromise
🎯 Why Choose GHM-RF-I?
| Problem | RF-I Solution |
|---|---|
| Staining and coverslipping are separate processes | All-in-one — both in 5 minutes |
| Coverslipping creates a bottleneck | 200 slides/hour — covers faster than you stain |
| Complex protocols take forever to program | Save 24 custom programs — switch stains instantly |
| Lab space is limited | Small footprint — fits on a standard bench |
| Technicians need to watch the machine constantly | Voice reminders — multitask with confidence |
| Inconsistent temperature ruins special stains | ±1°C accuracy — reproducible results every time |