🚀 200 Slides per Hour — Double the Throughput of RF-I

Upgrade your lab's capacity without upgrading your team. The RF-II delivers 200 slides per hour for staining and 300 slides per hour for coverslipping — exactly double the staining throughput of the RF-I. For coverslips alone, that's 1,200 coverslips per hour at peak capacity.

Why it matters: Process twice as many slides in the same shift. Perfect for mid-volume labs scaling up from entry-level automation without moving to a full industrial system.


⚡ Complete in 5 Minutes — Staining & Coverslipping Together

Just like its smaller sibling, the RF-II completes the entire staining and coverslipping process in just 5 minutes. Load a rack, press start, and walk away — both processes run simultaneously in a single integrated instrument.

Why it matters: No waiting for a separate coverslipper to catch up. No transferring wet slides between instruments. A true one-button, all-in-one solution.


🧪 27 Total Stations — 20 Reagent Stations — 450ml Containers

The RF-II significantly expands your staining capabilities:

  • 27 total stations (vs. 24 on RF-I)

  • 20 dedicated reagent stations — up from 16 on RF-I

  • 450ml reagent containers — nearly three times the volume of RF-I's 160ml containers

Why it matters: Run longer without refilling reagents. Accommodate more complex staining protocols. Perfect for high-volume H&E, special stains, and research applications where reagent top-ups disrupt workflow.


🧩 30-Slide Rack Capacity — Batch Processing at Scale

The RF-II accepts 30 slides per rack — a massive upgrade from RF-I's 8-slide capacity. The input/output drawer accommodates one rack at a time, but the larger rack size means fewer changeovers per run.

Why it matters: Process 30 slides in a single batch. Load once, walk away, return to 30 finished slides. Minimize technician hands-on time and maximize throughput.


📏 Macroslide Rack Available — Handle Large Specimens

Unlike the RF-I, the RF-II supports macroslide racks. This means you can process larger-format slides for whole-mount sections, breast cancer resection margins, and other macro specimens that won't fit on standard slides.

Why it matters: One instrument handles your entire case mix — from routine biopsies to large surgical resections. No need for a separate macroslide processing system.


🔬 4 Heated Stations with ±1°C Precision

The RF-II includes 4 reagent heating stations with precise temperature control from 0°C to 60°C, maintaining ±1°C accuracy. This matches the RF-I's heating precision but with larger reagent volumes.

Why it matters: Reproducible results run after run for temperature-sensitive protocols like special stains and immunohistochemistry. No hot spots, no cold spots — just consistent staining.


📱 11.6-Inch Touchscreen — Bigger, Clearer, Easier

The RF-II features an 11.6-inch color touchscreen — significantly larger than RF-I's 7-inch display. The intuitive interface makes program selection, status monitoring, and maintenance simple for all skill levels.

Why it matters: Less squinting, fewer errors. Technicians can monitor runs from across the room. Programming is straightforward, so training time is minimal.


💾 24 Custom Programs — Up to 54 Steps Each

Store up to 24 custom staining programs with up to 54 steps per program. Whether it's H&E, special stains, cytology, or research protocols, the RF-II adapts to your needs instantly.

Why it matters: Switch between stains in seconds. Validate and save your best protocols. Perfect for labs that run multiple stain types daily.


🛡️ Smart Coverslipping — 200 Coverslip Capacity, 300 Slides/Hour

The integrated coverslipper delivers 300 slides per hour — 50% faster than the RF-I's 200 slides/hour. Smart features include:

  • Defective coverslip detection — automatically rejects damaged or flawed coverslips

  • Empty coverslip detection — real-time monitoring of coverslip availability

  • Low inventory pre-alert — warns before coverslips run out

  • 200 coverslip storage capacity

Why it matters: No ruined slides from bad coverslips. No mid-run surprises. Your coverslipper runs smoothly from morning to evening with fewer refills.


🧩 90-Slide Output Rack Capacity

The RF-II's output rack holds 90 slides — dramatically larger than RF-I's 16-slide capacity. That's three full staining racks worth of finished slides waiting for the next step.

Why it matters: Less frequent unloading. Let the machine run while you attend to other duties. Perfect for labs that batch process and want minimal interruptions.


🔊 Voice Reminders — Keep Moving

The RF-II includes voice reminders to alert technicians when cycles complete, when reagents need attention, or when coverslips are running low.

Why it matters: Multitask without constantly watching the screen. Voice alerts mean you never miss a cycle completion, even across a busy lab.


📦 Compact Footprint for Mid-Volume Power

Dimensions: 1270mm × 590mm × 760mm (W×D×H). Weight: 130kg. The RF-II packs double the throughput of the RF-I into a footprint that fits through standard doorways and onto standard benches.

Why it matters: Massive throughput without massive space requirements. Easy to install, easy to maintain, easy to love.


🔌 CE-IVDR Certified — Ready for Diagnostic Labs

The RF-II is CE-IVDR certified, meeting the latest European regulatory standards for in vitro diagnostic medical devices.

Why it matters: Regulatory confidence for diagnostic labs worldwide. Deploy with assurance that your automation meets global standards.


🌍 Global Power Ready — 100–240V, 50/60Hz

Operates on 100–240V AC, 50/60Hz with interchangeable power sockets (Types A, C, D, E/F, G, I, J, L, M). Rated power: just 200VA.

Why it matters: Same instrument works anywhere in the world. No transformer needed. Low power consumption keeps operational costs down.


📊 Quick Specs — GHM-RF-II



Feature Specification
Staining throughput 200 slides per hour
Coverslipping throughput 300 slides per hour (1,200 coverslips/hour)
Complete cycle time 5 minutes (staining + coverslipping)
Total stations 27
Reagent stations 20 (450ml each)
Heated stations 4 (0°C–60°C, ±1°C accuracy)
Washing stations 4
Drying oven stations 1
Rack slides capacity 30 slides per rack
Macroslide support Yes (optional rack)
Program storage 24 programs, up to 54 steps each
Coverslip storage 200 coverslips (24×50mm)
Output rack capacity 90 slides
Coverslipping features Defective detection, empty detection, low inventory alert
Dimensions 1270 × 590 × 760 mm
Weight 130 kg
Screen 11.6-inch touchscreen with voice reminders
Power 100–240V, 50/60Hz, 200VA
Certification CE-IVDR

📈 RF Series Comparison — Where RF-II Fits



Feature RF‑I RF‑II (THIS MODEL) RF‑III RF‑V
Staining throughput 100/hr 200/hr 300/hr 600/hr
Coverslipping throughput 200/hr 300/hr 400/hr 600/hr
Rack slides capacity 8 30 30×2 30×10
Reagent stations 16 20 21–23 23–27
Reagent container volume 160ml 450ml 450ml 750ml
Macroslide support No Yes Yes Yes
Output rack capacity 16 90 120 360
Monitor size 7" 11.6" 11.6" + 8.8" 12" + 8.8"
Dimensions (mm) 920×530×550 1270×590×760 1528×625×705 1903×715×695
Weight 100kg 130kg 165kg 205kg
Best for Small-volume Mid-volume High-volume Industrial

Which one is right for you?

  • Choose RF-I if you process up to 100 slides/hour and need a compact entry point

  • Choose RF-II if you need 200 slides/hour with larger reagent volumes and macroslide support

  • Choose RF-III for 300+ slides/hour with expanded capacity

  • Choose RF-V for industrial-scale or core lab environments processing 600 slides/hour


💡 Perfect For

 Hospital pathology labs — Mid-volume H&E and special stain processing
 Reference laboratories — 200 slides/hour keeps pace with busy accessioning
 Research institutions — Macroslide support for whole-mount sections
 Teaching hospitals — Easy-to-operate system with flexible programming
 Scaling labs — The perfect upgrade from RF-I when volume grows


🎯 Why Upgrade to RF-II from RF-I?



RF-I Limitation RF-II Solution
100 slides/hour throughput 200 slides/hour — double the capacity
8-slide racks, constant changeovers 30-slide racks — fewer interruptions
160ml reagent containers, frequent refills 450ml containers — three times the volume
No macroslide support Macroslide rack available — handles large specimens
16-slide output capacity 90-slide output — less frequent unloading
7-inch screen 11.6-inch screen — easier to read and operate

📦 What's Included

  • GHM-RF-II Stainer and Coverslipper unit

  • Staining racks (30-slide capacity each)

  • Reagent containers (450ml each, 20 included)

  • Coverslip magazine (holds 200 coverslips, 24×50mm)

  • Output racks (90-slide total capacity)

  • Macroslide rack (optional — available on request)

  • Power cord (regional type supplied)

  • Quick start guide and protocol templates

  • 1-year warranty with technical support


🔧 What's in the Box — Shipping Configurations



Configuration Dimensions (W×L×H) Weight
Air freight crate 1390 × 710 × 940 mm 180 kg
Ocean freight wooden crate 1400 × 730 × 850 mm 160 kg

Why it matters: Multiple shipping options for global delivery. Air freight for urgent installations, ocean freight for cost-effective bulk shipping.

View full details