WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM RF-II Stainer and Coverslipper
GHM RF-II Stainer and Coverslipper
đ 200 Slides per Hour â Double the Throughput of RF-I
Upgrade your lab's capacity without upgrading your team. The RF-II delivers 200 slides per hour for staining and 300 slides per hour for coverslipping â exactly double the staining throughput of the RF-I. For coverslips alone, that's 1,200 coverslips per hour at peak capacity.
Why it matters:Â Process twice as many slides in the same shift. Perfect for mid-volume labs scaling up from entry-level automation without moving to a full industrial system.
⥠Complete in 5 Minutes â Staining & Coverslipping Together
Just like its smaller sibling, the RF-II completes the entire staining and coverslipping process in just 5 minutes. Load a rack, press start, and walk away â both processes run simultaneously in a single integrated instrument.
Why it matters:Â No waiting for a separate coverslipper to catch up. No transferring wet slides between instruments. A true one-button, all-in-one solution.
đ§Ș 27 Total Stations â 20 Reagent Stations â 450ml Containers
The RF-II significantly expands your staining capabilities:
-
27 total stations (vs. 24 on RF-I)
-
20 dedicated reagent stations â up from 16 on RF-I
-
450ml reagent containers â nearly three times the volume of RF-I's 160ml containers
Why it matters:Â Run longer without refilling reagents. Accommodate more complex staining protocols. Perfect for high-volume H&E, special stains, and research applications where reagent top-ups disrupt workflow.
đ§© 30-Slide Rack Capacity â Batch Processing at Scale
The RF-II accepts 30 slides per rack â a massive upgrade from RF-I's 8-slide capacity. The input/output drawer accommodates one rack at a time, but the larger rack size means fewer changeovers per run.
Why it matters:Â Process 30 slides in a single batch. Load once, walk away, return to 30 finished slides. Minimize technician hands-on time and maximize throughput.
đ Macroslide Rack Available â Handle Large Specimens
Unlike the RF-I, the RF-IIÂ supports macroslide racks. This means you can process larger-format slides for whole-mount sections, breast cancer resection margins, and other macro specimens that won't fit on standard slides.
Why it matters:Â One instrument handles your entire case mix â from routine biopsies to large surgical resections. No need for a separate macroslide processing system.
đŹ 4 Heated Stations with ±1°C Precision
The RF-II includes 4 reagent heating stations with precise temperature control from 0°C to 60°C, maintaining ±1°C accuracy. This matches the RF-I's heating precision but with larger reagent volumes.
Why it matters:Â Reproducible results run after run for temperature-sensitive protocols like special stains and immunohistochemistry. No hot spots, no cold spots â just consistent staining.
đ± 11.6-Inch Touchscreen â Bigger, Clearer, Easier
The RF-II features an 11.6-inch color touchscreen â significantly larger than RF-I's 7-inch display. The intuitive interface makes program selection, status monitoring, and maintenance simple for all skill levels.
Why it matters:Â Less squinting, fewer errors. Technicians can monitor runs from across the room. Programming is straightforward, so training time is minimal.
đŸ 24 Custom Programs â Up to 54 Steps Each
Store up to 24 custom staining programs with up to 54 steps per program. Whether it's H&E, special stains, cytology, or research protocols, the RF-II adapts to your needs instantly.
Why it matters:Â Switch between stains in seconds. Validate and save your best protocols. Perfect for labs that run multiple stain types daily.
đĄïž Smart Coverslipping â 200 Coverslip Capacity, 300 Slides/Hour
The integrated coverslipper delivers 300 slides per hour â 50% faster than the RF-I's 200 slides/hour. Smart features include:
-
Defective coverslip detection â automatically rejects damaged or flawed coverslips
-
Empty coverslip detection â real-time monitoring of coverslip availability
-
Low inventory pre-alert â warns before coverslips run out
Why it matters:Â No ruined slides from bad coverslips. No mid-run surprises. Your coverslipper runs smoothly from morning to evening with fewer refills.
đ§© 90-Slide Output Rack Capacity
The RF-II's output rack holds 90 slides â dramatically larger than RF-I's 16-slide capacity. That's three full staining racks worth of finished slides waiting for the next step.
Why it matters:Â Less frequent unloading. Let the machine run while you attend to other duties. Perfect for labs that batch process and want minimal interruptions.
đ Voice Reminders â Keep Moving
The RF-II includes voice reminders to alert technicians when cycles complete, when reagents need attention, or when coverslips are running low.
Why it matters:Â Multitask without constantly watching the screen. Voice alerts mean you never miss a cycle completion, even across a busy lab.
đŠ Compact Footprint for Mid-Volume Power
Dimensions: 1270mm Ă 590mm Ă 760mm (WĂDĂH). Weight: 130kg. The RF-II packs double the throughput of the RF-I into a footprint that fits through standard doorways and onto standard benches.
Why it matters:Â Massive throughput without massive space requirements. Easy to install, easy to maintain, easy to love.
đ CE-IVDR Certified â Ready for Diagnostic Labs
The RF-II is CE-IVDR certified, meeting the latest European regulatory standards for in vitro diagnostic medical devices.
Why it matters:Â Regulatory confidence for diagnostic labs worldwide. Deploy with assurance that your automation meets global standards.
đ Global Power Ready â 100â240V, 50/60Hz
Operates on 100â240V AC, 50/60Hz with interchangeable power sockets (Types A, C, D, E/F, G, I, J, L, M). Rated power: just 200VA.
Why it matters:Â Same instrument works anywhere in the world. No transformer needed. Low power consumption keeps operational costs down.
đ Quick Specs â GHM-RF-II
| Feature | Specification |
|---|---|
| Staining throughput | 200 slides per hour |
| Coverslipping throughput | 300 slides per hour (1,200 coverslips/hour) |
| Complete cycle time | 5 minutes (staining + coverslipping) |
| Total stations | 27 |
| Reagent stations | 20 (450ml each) |
| Heated stations | 4 (0°Câ60°C, ±1°C accuracy) |
| Washing stations | 4 |
| Drying oven stations | 1 |
| Rack slides capacity | 30 slides per rack |
| Macroslide support | Yes (optional rack) |
| Program storage | 24 programs, up to 54 steps each |
| Coverslip storage | 200 coverslips (24Ă50mm) |
| Output rack capacity | 90 slides |
| Coverslipping features | Defective detection, empty detection, low inventory alert |
| Dimensions | 1270 Ă 590 Ă 760 mm |
| Weight | 130 kg |
| Screen | 11.6-inch touchscreen with voice reminders |
| Power | 100â240V, 50/60Hz, 200VA |
| Certification | CE-IVDR |
đ RF Series Comparison â Where RF-II Fits
| Feature | RFâI | RFâII (THIS MODEL) | RFâIII | RFâV |
|---|---|---|---|---|
| Staining throughput | 100/hr | 200/hr | 300/hr | 600/hr |
| Coverslipping throughput | 200/hr | 300/hr | 400/hr | 600/hr |
| Rack slides capacity | 8 | 30 | 30Ă2 | 30Ă10 |
| Reagent stations | 16 | 20 | 21â23 | 23â27 |
| Reagent container volume | 160ml | 450ml | 450ml | 750ml |
| Macroslide support | No | Yes | Yes | Yes |
| Output rack capacity | 16 | 90 | 120 | 360 |
| Monitor size | 7" | 11.6" | 11.6" + 8.8" | 12" + 8.8" |
| Dimensions (mm) | 920Ă530Ă550 | 1270Ă590Ă760 | 1528Ă625Ă705 | 1903Ă715Ă695 |
| Weight | 100kg | 130kg | 165kg | 205kg |
| Best for | Small-volume | Mid-volume | High-volume | Industrial |
Which one is right for you?
-
Choose RF-IÂ if you process up to 100 slides/hour and need a compact entry point
-
Choose RF-IIÂ if you need 200 slides/hour with larger reagent volumes and macroslide support
-
Choose RF-IIIÂ for 300+ slides/hour with expanded capacity
-
Choose RF-VÂ for industrial-scale or core lab environments processing 600 slides/hour
đĄ Perfect For
â
 Hospital pathology labs â Mid-volume H&E and special stain processing
â
 Reference laboratories â 200 slides/hour keeps pace with busy accessioning
â
 Research institutions â Macroslide support for whole-mount sections
â
 Teaching hospitals â Easy-to-operate system with flexible programming
â
 Scaling labs â The perfect upgrade from RF-I when volume grows
đŻ Why Upgrade to RF-II from RF-I?
| RF-I Limitation | RF-II Solution |
|---|---|
| 100 slides/hour throughput | 200 slides/hour â double the capacity |
| 8-slide racks, constant changeovers | 30-slide racks â fewer interruptions |
| 160ml reagent containers, frequent refills | 450ml containers â three times the volume |
| No macroslide support | Macroslide rack available â handles large specimens |
| 16-slide output capacity | 90-slide output â less frequent unloading |
| 7-inch screen | 11.6-inch screen â easier to read and operate |
đŠ What's Included
-
GHM-RF-II Stainer and Coverslipper unit
-
Staining racks (30-slide capacity each)
-
Reagent containers (450ml each, 20 included)
-
Coverslip magazine (holds 200 coverslips, 24Ă50mm)
-
Output racks (90-slide total capacity)
-
Macroslide rack (optional â available on request)
-
Power cord (regional type supplied)
-
Quick start guide and protocol templates
-
1-year warranty with technical support
đ§ What's in the Box â Shipping Configurations
| Configuration | Dimensions (WĂLĂH) | Weight |
|---|---|---|
| Air freight crate | 1390 Ă 710 Ă 940 mm | 180 kg |
| Ocean freight wooden crate | 1400 Ă 730 Ă 850 mm | 160 kg |
Why it matters:Â Multiple shipping options for global delivery. Air freight for urgent installations, ocean freight for cost-effective bulk shipping.