Contact via WhatsApp: +81 9022195237
Global Healthcare Medical
GHM RF-III Stainer and Coverslipper #
GHM RF-III Stainer and Coverslipper #
Couldn't load pickup availability
🚀 300 Slides per Hour — 3× the Throughput of Entry-Level Models
The RF-III delivers 300 slides per hour for staining and 400 slides per hour for coverslipping — triple the throughput of the RF-I and 1.5× that of the RF-II. For coverslips alone, that's 1,600 coverslips per hour at peak capacity.
Why it matters: Process high-volume batches without bottlenecks. Perfect for busy hospital labs, reference laboratories, and core facilities where every minute of throughput matters.
⚡ Complete in 5 Minutes — Staining & Coverslipping Together
Just like the rest of the RF series, the RF-III completes the entire staining and coverslipping process in just 5 minutes. Load racks, press start, and walk away — both processes run simultaneously in a single integrated instrument.
Why it matters: No waiting for a separate coverslipper to catch up. No transferring wet slides between instruments. A true one-button, all-in-one solution.
🧪 30 Total Stations — 21–23 Reagent Stations — Expandable
The RF-III features 30 total stations — significantly more than the RF-II (27) and RF-I (24). Reagent stations are standard at 21, expandable up to 23, with 450ml reagent containers matching the RF-II's larger volume.
Why it matters: Accommodate complex, multi-step staining protocols without reconfiguring the instrument. Expand reagent capacity as your menu grows. Run longer between refills.
🧩 2× Racks, 60 Slides Simultaneous Loading
The RF-III accepts two staining racks simultaneously, each holding 30 slides — for a total of 60 slides in process at once. The input/output drawer accommodates 3 stations for continuous loading.
Why it matters: Load one rack while another is processing. Zero downtime between batches. Perfect for continuous, high-throughput workflows where technicians load throughout the day.
📏 Macroslide Support — Handle Large Specimens
Like the RF-II, the RF-III supports macroslide racks. Process larger-format slides for whole-mount sections, breast cancer resection margins, and other macro specimens that won't fit on standard slides.
Why it matters: One instrument handles your entire case mix — from routine biopsies to large surgical resections. No need for a separate macroslide processing system.
🔬 4 Heated Stations with ±1°C Precision
The RF-III includes 4 reagent heating stations with precise temperature control from 0°C to 60°C, maintaining ±1°C accuracy.
Why it matters: Reproducible results run after run for temperature-sensitive protocols like special stains and immunohistochemistry. No hot spots, no cold spots — just consistent staining.
📱 11.6-Inch Touchscreen + 8.8-Inch Secondary Display
The RF-III features an 11.6-inch primary touchscreen (same as RF-II) plus a dedicated 8.8-inch monitor for the coverslipper module — a dual-screen setup unique in the series below the RF-V.
Why it matters: Monitor staining and coverslipping simultaneously. Dedicated coverslipper display shows real-time inventory, error alerts, and status without interrupting the staining interface.
💾 24 Custom Programs — Up to 54 Steps Each
Store up to 24 custom staining programs with up to 54 steps per program. Whether it's H&E, special stains, cytology, or research protocols, the RF-III adapts to your needs instantly.
Why it matters: Switch between stains in seconds. Validate and save your best protocols. Perfect for labs that run multiple stain types daily.
🛡️ Smart Coverslipping — 600 Coverslip Capacity, 400 Slides/Hour
The integrated coverslipper delivers 400 slides per hour — 33% faster than RF-II and double RF-I's speed. Smart features include:
-
Defective coverslip detection — automatically rejects damaged or flawed coverslips
-
Empty coverslip detection — real-time monitoring of coverslip availability
-
Low inventory pre-alert — warns before coverslips run out
-
600 coverslip storage capacity — 3× the capacity of RF-I and RF-II
Why it matters: No ruined slides from bad coverslips. No mid-run surprises. Run longer between refills with 3× the coverslip storage.
🧩 120-Slide Output Rack Capacity
The RF-III's output rack holds 120 slides — 4 full staining racks' worth of finished slides waiting for the next step. That's 33% more than RF-II's 90-slide output.
Why it matters: Less frequent unloading. Let the machine run while you attend to other duties. Perfect for labs that batch process and want minimal interruptions.
🔊 Voice Reminders — Keep Moving
The RF-III includes voice reminders to alert technicians when cycles complete, when reagents need attention, or when coverslips are running low.
Why it matters: Multitask without constantly watching the screen. Voice alerts mean you never miss a cycle completion, even across a busy lab.
📦 Optimized Footprint for High-Volume Power
Dimensions: 1528mm × 625mm × 705mm (W×D×H). Weight: 165kg. The RF-III packs 300 slides/hour throughput into a footprint only 258mm wider and 35mm deeper than the RF-II.
Why it matters: Massive throughput without massive space requirements. Fits through standard doorways and onto standard lab benches.
🔌 CE-IVDR Certified — Ready for Diagnostic Labs
The RF-III is CE-IVDR certified, meeting the latest European regulatory standards for in vitro diagnostic medical devices.
Why it matters: Regulatory confidence for diagnostic labs worldwide. Deploy with assurance that your automation meets global standards.
🌍 Global Power Ready — 100–240V, 50/60Hz
Operates on 100–240V AC, 50/60Hz with interchangeable power sockets (Types A, C, D, E/F, G, I, J, L, M). Rated power: just 200VA.
Why it matters: Same instrument works anywhere in the world. No transformer needed. Low power consumption keeps operational costs down.
📊 Quick Specs — GHM-RF-III
| Feature | Specification |
|---|---|
| Staining throughput | 300 slides per hour |
| Coverslipping throughput | 400 slides per hour (1,600 coverslips/hour) |
| Complete cycle time | 5 minutes (staining + coverslipping) |
| Total stations | 30 |
| Reagent stations | 21 (expandable to 23) — 450ml each |
| Heated stations | 4 (0°C–60°C, ±1°C accuracy) |
| Washing stations | 4 |
| Drying oven stations | 1 |
| Rack slides capacity | 30 slides per rack × 2 racks simultaneously |
| In staining rack capacity | 12 slides |
| Macroslide support | Yes |
| Program storage | 24 programs, up to 54 steps each |
| Coverslip storage | 600 coverslips (24×50mm) |
| Output rack capacity | 120 slides |
| Coverslipping features | Defective detection, empty detection, low inventory alert |
| Dimensions | 1528 × 625 × 705 mm |
| Weight | 165 kg |
| Screens | 11.6-inch primary + 8.8-inch coverslipper display |
| Voice reminders | Yes |
| Power | 100–240V, 50/60Hz, 200VA |
| Certification | CE-IVDR |
📦 Shipping Configurations
| Configuration | Dimensions (W×L×H) | Weight |
|---|---|---|
| Air freight crate | 1710 × 720 × 965 mm | 235 kg |
| Ocean freight wooden crate | 1730 × 740 × 875 mm | 210 kg |
📈 KF-RF Series Comparison — Where RF-III Fits
| Feature | RF‑I | RF‑II | RF‑III (THIS MODEL) | RF‑V |
|---|---|---|---|---|
| Staining throughput | 100/hr | 200/hr | 300/hr | 600/hr |
| Coverslipping throughput | 200/hr | 300/hr | 400/hr | 600/hr |
| Rack slides capacity | 8 | 30 | 30 × 2 | 30 × 10 |
| Total stations | 24 | 27 | 30 | 35 |
| Reagent stations | 16 | 20 | 21–23 (expandable) | 23–27 |
| Reagent container volume | 160ml | 450ml | 450ml | 750ml |
| Macroslide support | No | Yes | Yes | Yes |
| Coverslip storage | 200 | 200 | 600 | 800 |
| Output rack capacity | 16 | 90 | 120 | 360 |
| In staining rack capacity | 10 | 10 | 12 | 22 |
| Monitor size | 7" | 11.6" | 11.6" + 8.8" | 12" + 8.8" |
| Dimensions (mm) | 920×530×550 | 1270×590×760 | 1528×625×705 | 1903×715×695 |
| Weight | 100kg | 130kg | 165kg | 205kg |
| Best for | Small-volume | Mid-volume | High-volume | Industrial |
Which one is right for you?
-
Choose RF-I if you process up to 100 slides/hour and need a compact entry point
-
Choose RF-II if you need 200 slides/hour with macroslide support
-
Choose RF-III if you need 300 slides/hour with dual-rack simultaneous loading and 600 coverslip capacity
-
Choose RF-V for industrial-scale labs processing 600 slides/hour
💡 Perfect For
✅ Hospital pathology labs — High-volume H&E and special stain processing
✅ Reference laboratories — 300 slides/hour keeps pace with high accessioning volumes
✅ Core research facilities — Multi-user, multi-protocol flexibility
✅ Teaching hospitals — Dual-screen interface simplifies training
✅ Scaling labs — The natural upgrade from RF-II when volume crosses 200 slides/hour
🎯 Why Upgrade to RF-III from RF-II?
| RF-II Limitation | RF-III Solution |
|---|---|
| 200 slides/hour staining | 300 slides/hour — 50% more capacity |
| 30 slides at a time | 60 slides simultaneously — dual racks |
| 27 total stations | 30 total stations — more protocol flexibility |
| 200 coverslip storage | 600 coverslip storage — 3× the capacity |
| 90-slide output | 120-slide output — 33% more |
| Single 11.6" screen | Dual screens — staining + coverslipping visibility |
📦 What's Included
-
GHM-RF-III Stainer and Coverslipper unit
-
Staining racks (30-slide capacity each, 2 included)
-
Reagent containers (450ml each, 21 included, expandable to 23)
-
Coverslip magazine (holds 600 coverslips, 24×50mm)
-
Output racks (120-slide total capacity)
-
Macroslide rack (available on request)
-
Power cord (regional type supplied)
-
Quick start guide and protocol templates
-
1-year warranty with technical support
Share