WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM RF-III Stainer and Coverslipper
GHM RF-III Stainer and Coverslipper
đ 300 Slides per Hour â 3Ă the Throughput of Entry-Level Models
The RF-III delivers 300 slides per hour for staining and 400 slides per hour for coverslipping â triple the throughput of the RF-I and 1.5Ă that of the RF-II. For coverslips alone, that's 1,600 coverslips per hour at peak capacity.
Why it matters:Â Process high-volume batches without bottlenecks. Perfect for busy hospital labs, reference laboratories, and core facilities where every minute of throughput matters.
⥠Complete in 5 Minutes â Staining & Coverslipping Together
Just like the rest of the RF series, the RF-III completes the entire staining and coverslipping process in just 5 minutes. Load racks, press start, and walk away â both processes run simultaneously in a single integrated instrument.
Why it matters:Â No waiting for a separate coverslipper to catch up. No transferring wet slides between instruments. A true one-button, all-in-one solution.
đ§Ș 30 Total Stations â 21â23 Reagent Stations â Expandable
The RF-III features 30 total stations â significantly more than the RF-II (27) and RF-I (24). Reagent stations are standard at 21, expandable up to 23, with 450ml reagent containers matching the RF-II's larger volume.
Why it matters:Â Accommodate complex, multi-step staining protocols without reconfiguring the instrument. Expand reagent capacity as your menu grows. Run longer between refills.
đ§© 2Ă Racks, 60 Slides Simultaneous Loading
The RF-III accepts two staining racks simultaneously, each holding 30 slides â for a total of 60 slides in process at once. The input/output drawer accommodates 3 stations for continuous loading.
Why it matters:Â Load one rack while another is processing. Zero downtime between batches. Perfect for continuous, high-throughput workflows where technicians load throughout the day.
đ Macroslide Support â Handle Large Specimens
Like the RF-II, the RF-IIIÂ supports macroslide racks. Process larger-format slides for whole-mount sections, breast cancer resection margins, and other macro specimens that won't fit on standard slides.
Why it matters:Â One instrument handles your entire case mix â from routine biopsies to large surgical resections. No need for a separate macroslide processing system.
đŹ 4 Heated Stations with ±1°C Precision
The RF-III includes 4 reagent heating stations with precise temperature control from 0°C to 60°C, maintaining ±1°C accuracy.
Why it matters:Â Reproducible results run after run for temperature-sensitive protocols like special stains and immunohistochemistry. No hot spots, no cold spots â just consistent staining.
đ± 11.6-Inch Touchscreen + 8.8-Inch Secondary Display
The RF-III features an 11.6-inch primary touchscreen (same as RF-II) plus a dedicated 8.8-inch monitor for the coverslipper module â a dual-screen setup unique in the series below the RF-V.
Why it matters:Â Monitor staining and coverslipping simultaneously. Dedicated coverslipper display shows real-time inventory, error alerts, and status without interrupting the staining interface.
đŸ 24 Custom Programs â Up to 54 Steps Each
Store up to 24 custom staining programs with up to 54 steps per program. Whether it's H&E, special stains, cytology, or research protocols, the RF-III adapts to your needs instantly.
Why it matters:Â Switch between stains in seconds. Validate and save your best protocols. Perfect for labs that run multiple stain types daily.
đĄïž Smart Coverslipping â 600 Coverslip Capacity, 400 Slides/Hour
The integrated coverslipper delivers 400 slides per hour â 33% faster than RF-II and double RF-I's speed. Smart features include:
-
Defective coverslip detection â automatically rejects damaged or flawed coverslips
-
Empty coverslip detection â real-time monitoring of coverslip availability
-
Low inventory pre-alert â warns before coverslips run out
-
600 coverslip storage capacity â 3Ă the capacity of RF-I and RF-II
Why it matters:Â No ruined slides from bad coverslips. No mid-run surprises. Run longer between refills with 3Ă the coverslip storage.
đ§© 120-Slide Output Rack Capacity
The RF-III's output rack holds 120 slides â 4 full staining racks' worth of finished slides waiting for the next step. That's 33% more than RF-II's 90-slide output.
Why it matters:Â Less frequent unloading. Let the machine run while you attend to other duties. Perfect for labs that batch process and want minimal interruptions.
đ Voice Reminders â Keep Moving
The RF-III includes voice reminders to alert technicians when cycles complete, when reagents need attention, or when coverslips are running low.
Why it matters:Â Multitask without constantly watching the screen. Voice alerts mean you never miss a cycle completion, even across a busy lab.
đŠ Optimized Footprint for High-Volume Power
Dimensions: 1528mm Ă 625mm Ă 705mm (WĂDĂH). Weight: 165kg. The RF-III packs 300 slides/hour throughput into a footprint only 258mm wider and 35mm deeper than the RF-II.
Why it matters:Â Massive throughput without massive space requirements. Fits through standard doorways and onto standard lab benches.
đ CE-IVDR Certified â Ready for Diagnostic Labs
The RF-III is CE-IVDR certified, meeting the latest European regulatory standards for in vitro diagnostic medical devices.
Why it matters:Â Regulatory confidence for diagnostic labs worldwide. Deploy with assurance that your automation meets global standards.
đ Global Power Ready â 100â240V, 50/60Hz
Operates on 100â240V AC, 50/60Hz with interchangeable power sockets (Types A, C, D, E/F, G, I, J, L, M). Rated power: just 200VA.
Why it matters:Â Same instrument works anywhere in the world. No transformer needed. Low power consumption keeps operational costs down.
đ Quick Specs â GHM-RF-III
| Feature | Specification |
|---|---|
| Staining throughput | 300 slides per hour |
| Coverslipping throughput | 400 slides per hour (1,600 coverslips/hour) |
| Complete cycle time | 5 minutes (staining + coverslipping) |
| Total stations | 30 |
| Reagent stations | 21 (expandable to 23) â 450ml each |
| Heated stations | 4 (0°Câ60°C, ±1°C accuracy) |
| Washing stations | 4 |
| Drying oven stations | 1 |
| Rack slides capacity | 30 slides per rack Ă 2 racks simultaneously |
| In staining rack capacity | 12 slides |
| Macroslide support | Yes |
| Program storage | 24 programs, up to 54 steps each |
| Coverslip storage | 600 coverslips (24Ă50mm) |
| Output rack capacity | 120 slides |
| Coverslipping features | Defective detection, empty detection, low inventory alert |
| Dimensions | 1528 Ă 625 Ă 705 mm |
| Weight | 165 kg |
| Screens | 11.6-inch primary + 8.8-inch coverslipper display |
| Voice reminders | Yes |
| Power | 100â240V, 50/60Hz, 200VA |
| Certification | CE-IVDR |
đŠ Shipping Configurations
| Configuration | Dimensions (WĂLĂH) | Weight |
|---|---|---|
| Air freight crate | 1710 Ă 720 Ă 965 mm | 235 kg |
| Ocean freight wooden crate | 1730 Ă 740 Ă 875 mm | 210 kg |
đ KF-RF Series Comparison â Where RF-III Fits
| Feature | RFâI | RFâII | RFâIII (THIS MODEL) | RFâV |
|---|---|---|---|---|
| Staining throughput | 100/hr | 200/hr | 300/hr | 600/hr |
| Coverslipping throughput | 200/hr | 300/hr | 400/hr | 600/hr |
| Rack slides capacity | 8 | 30 | 30 Ă 2 | 30 Ă 10 |
| Total stations | 24 | 27 | 30 | 35 |
| Reagent stations | 16 | 20 | 21â23 (expandable) | 23â27 |
| Reagent container volume | 160ml | 450ml | 450ml | 750ml |
| Macroslide support | No | Yes | Yes | Yes |
| Coverslip storage | 200 | 200 | 600 | 800 |
| Output rack capacity | 16 | 90 | 120 | 360 |
| In staining rack capacity | 10 | 10 | 12 | 22 |
| Monitor size | 7" | 11.6" | 11.6" + 8.8" | 12" + 8.8" |
| Dimensions (mm) | 920Ă530Ă550 | 1270Ă590Ă760 | 1528Ă625Ă705 | 1903Ă715Ă695 |
| Weight | 100kg | 130kg | 165kg | 205kg |
| Best for | Small-volume | Mid-volume | High-volume | Industrial |
Which one is right for you?
-
Choose RF-IÂ if you process up to 100 slides/hour and need a compact entry point
-
Choose RF-IIÂ if you need 200 slides/hour with macroslide support
-
Choose RF-IIIÂ if you need 300 slides/hour with dual-rack simultaneous loading and 600 coverslip capacity
-
Choose RF-VÂ for industrial-scale labs processing 600 slides/hour
đĄ Perfect For
â
 Hospital pathology labs â High-volume H&E and special stain processing
â
 Reference laboratories â 300 slides/hour keeps pace with high accessioning volumes
â
 Core research facilities â Multi-user, multi-protocol flexibility
â
 Teaching hospitals â Dual-screen interface simplifies training
â
 Scaling labs â The natural upgrade from RF-II when volume crosses 200 slides/hour
đŻ Why Upgrade to RF-III from RF-II?
| RF-II Limitation | RF-III Solution |
|---|---|
| 200 slides/hour staining | 300 slides/hour â 50% more capacity |
| 30 slides at a time | 60 slides simultaneously â dual racks |
| 27 total stations | 30 total stations â more protocol flexibility |
| 200 coverslip storage | 600 coverslip storage â 3Ă the capacity |
| 90-slide output | 120-slide output â 33% more |
| Single 11.6" screen | Dual screens â staining + coverslipping visibility |
đŠ What's Included
-
GHM-RF-III Stainer and Coverslipper unit
-
Staining racks (30-slide capacity each, 2 included)
-
Reagent containers (450ml each, 21 included, expandable to 23)
-
Coverslip magazine (holds 600 coverslips, 24Ă50mm)
-
Output racks (120-slide total capacity)
-
Macroslide rack (available on request)
-
Power cord (regional type supplied)
-
Quick start guide and protocol templates
-
1-year warranty with technical support