Skip to product information
1 of 1

Contact via WhatsApp: +81 9022195237

Global Healthcare Medical

GHM RF-III Stainer and Coverslipper #

GHM RF-III Stainer and Coverslipper #

Regular price $54,000.00
Regular price Sale price $54,000.00
Sale Sold out
Shipping calculated at checkout.

🚀 300 Slides per Hour — 3× the Throughput of Entry-Level Models

The RF-III delivers 300 slides per hour for staining and 400 slides per hour for coverslipping — triple the throughput of the RF-I and 1.5× that of the RF-II. For coverslips alone, that's 1,600 coverslips per hour at peak capacity.

Why it matters: Process high-volume batches without bottlenecks. Perfect for busy hospital labs, reference laboratories, and core facilities where every minute of throughput matters.


⚡ Complete in 5 Minutes — Staining & Coverslipping Together

Just like the rest of the RF series, the RF-III completes the entire staining and coverslipping process in just 5 minutes. Load racks, press start, and walk away — both processes run simultaneously in a single integrated instrument.

Why it matters: No waiting for a separate coverslipper to catch up. No transferring wet slides between instruments. A true one-button, all-in-one solution.


🧪 30 Total Stations — 21–23 Reagent Stations — Expandable

The RF-III features 30 total stations — significantly more than the RF-II (27) and RF-I (24). Reagent stations are standard at 21, expandable up to 23, with 450ml reagent containers matching the RF-II's larger volume.

Why it matters: Accommodate complex, multi-step staining protocols without reconfiguring the instrument. Expand reagent capacity as your menu grows. Run longer between refills.


🧩 2× Racks, 60 Slides Simultaneous Loading

The RF-III accepts two staining racks simultaneously, each holding 30 slides — for a total of 60 slides in process at once. The input/output drawer accommodates 3 stations for continuous loading.

Why it matters: Load one rack while another is processing. Zero downtime between batches. Perfect for continuous, high-throughput workflows where technicians load throughout the day.


📏 Macroslide Support — Handle Large Specimens

Like the RF-II, the RF-III supports macroslide racks. Process larger-format slides for whole-mount sections, breast cancer resection margins, and other macro specimens that won't fit on standard slides.

Why it matters: One instrument handles your entire case mix — from routine biopsies to large surgical resections. No need for a separate macroslide processing system.


🔬 4 Heated Stations with ±1°C Precision

The RF-III includes 4 reagent heating stations with precise temperature control from 0°C to 60°C, maintaining ±1°C accuracy.

Why it matters: Reproducible results run after run for temperature-sensitive protocols like special stains and immunohistochemistry. No hot spots, no cold spots — just consistent staining.


📱 11.6-Inch Touchscreen + 8.8-Inch Secondary Display

The RF-III features an 11.6-inch primary touchscreen (same as RF-II) plus a dedicated 8.8-inch monitor for the coverslipper module — a dual-screen setup unique in the series below the RF-V.

Why it matters: Monitor staining and coverslipping simultaneously. Dedicated coverslipper display shows real-time inventory, error alerts, and status without interrupting the staining interface.


💾 24 Custom Programs — Up to 54 Steps Each

Store up to 24 custom staining programs with up to 54 steps per program. Whether it's H&E, special stains, cytology, or research protocols, the RF-III adapts to your needs instantly.

Why it matters: Switch between stains in seconds. Validate and save your best protocols. Perfect for labs that run multiple stain types daily.


🛡️ Smart Coverslipping — 600 Coverslip Capacity, 400 Slides/Hour

The integrated coverslipper delivers 400 slides per hour — 33% faster than RF-II and double RF-I's speed. Smart features include:

  • Defective coverslip detection — automatically rejects damaged or flawed coverslips

  • Empty coverslip detection — real-time monitoring of coverslip availability

  • Low inventory pre-alert — warns before coverslips run out

  • 600 coverslip storage capacity — 3× the capacity of RF-I and RF-II

Why it matters: No ruined slides from bad coverslips. No mid-run surprises. Run longer between refills with 3× the coverslip storage.


🧩 120-Slide Output Rack Capacity

The RF-III's output rack holds 120 slides — 4 full staining racks' worth of finished slides waiting for the next step. That's 33% more than RF-II's 90-slide output.

Why it matters: Less frequent unloading. Let the machine run while you attend to other duties. Perfect for labs that batch process and want minimal interruptions.


🔊 Voice Reminders — Keep Moving

The RF-III includes voice reminders to alert technicians when cycles complete, when reagents need attention, or when coverslips are running low.

Why it matters: Multitask without constantly watching the screen. Voice alerts mean you never miss a cycle completion, even across a busy lab.


📦 Optimized Footprint for High-Volume Power

Dimensions: 1528mm × 625mm × 705mm (W×D×H). Weight: 165kg. The RF-III packs 300 slides/hour throughput into a footprint only 258mm wider and 35mm deeper than the RF-II.

Why it matters: Massive throughput without massive space requirements. Fits through standard doorways and onto standard lab benches.


🔌 CE-IVDR Certified — Ready for Diagnostic Labs

The RF-III is CE-IVDR certified, meeting the latest European regulatory standards for in vitro diagnostic medical devices.

Why it matters: Regulatory confidence for diagnostic labs worldwide. Deploy with assurance that your automation meets global standards.


🌍 Global Power Ready — 100–240V, 50/60Hz

Operates on 100–240V AC, 50/60Hz with interchangeable power sockets (Types A, C, D, E/F, G, I, J, L, M). Rated power: just 200VA.

Why it matters: Same instrument works anywhere in the world. No transformer needed. Low power consumption keeps operational costs down.


📊 Quick Specs — GHM-RF-III



Feature Specification
Staining throughput 300 slides per hour
Coverslipping throughput 400 slides per hour (1,600 coverslips/hour)
Complete cycle time 5 minutes (staining + coverslipping)
Total stations 30
Reagent stations 21 (expandable to 23) — 450ml each
Heated stations 4 (0°C–60°C, ±1°C accuracy)
Washing stations 4
Drying oven stations 1
Rack slides capacity 30 slides per rack × 2 racks simultaneously
In staining rack capacity 12 slides
Macroslide support Yes
Program storage 24 programs, up to 54 steps each
Coverslip storage 600 coverslips (24×50mm)
Output rack capacity 120 slides
Coverslipping features Defective detection, empty detection, low inventory alert
Dimensions 1528 × 625 × 705 mm
Weight 165 kg
Screens 11.6-inch primary + 8.8-inch coverslipper display
Voice reminders Yes
Power 100–240V, 50/60Hz, 200VA
Certification CE-IVDR

📦 Shipping Configurations



Configuration Dimensions (W×L×H) Weight
Air freight crate 1710 × 720 × 965 mm 235 kg
Ocean freight wooden crate 1730 × 740 × 875 mm 210 kg

📈 KF-RF Series Comparison — Where RF-III Fits



Feature RF‑I RF‑II RF‑III (THIS MODEL) RF‑V
Staining throughput 100/hr 200/hr 300/hr 600/hr
Coverslipping throughput 200/hr 300/hr 400/hr 600/hr
Rack slides capacity 8 30 30 × 2 30 × 10
Total stations 24 27 30 35
Reagent stations 16 20 21–23 (expandable) 23–27
Reagent container volume 160ml 450ml 450ml 750ml
Macroslide support No Yes Yes Yes
Coverslip storage 200 200 600 800
Output rack capacity 16 90 120 360
In staining rack capacity 10 10 12 22
Monitor size 7" 11.6" 11.6" + 8.8" 12" + 8.8"
Dimensions (mm) 920×530×550 1270×590×760 1528×625×705 1903×715×695
Weight 100kg 130kg 165kg 205kg
Best for Small-volume Mid-volume High-volume Industrial

Which one is right for you?

  • Choose RF-I if you process up to 100 slides/hour and need a compact entry point

  • Choose RF-II if you need 200 slides/hour with macroslide support

  • Choose RF-III if you need 300 slides/hour with dual-rack simultaneous loading and 600 coverslip capacity

  • Choose RF-V for industrial-scale labs processing 600 slides/hour


💡 Perfect For

 Hospital pathology labs — High-volume H&E and special stain processing
 Reference laboratories — 300 slides/hour keeps pace with high accessioning volumes
 Core research facilities — Multi-user, multi-protocol flexibility
 Teaching hospitals — Dual-screen interface simplifies training
 Scaling labs — The natural upgrade from RF-II when volume crosses 200 slides/hour


🎯 Why Upgrade to RF-III from RF-II?



RF-II Limitation RF-III Solution
200 slides/hour staining 300 slides/hour — 50% more capacity
30 slides at a time 60 slides simultaneously — dual racks
27 total stations 30 total stations — more protocol flexibility
200 coverslip storage 600 coverslip storage — 3× the capacity
90-slide output 120-slide output — 33% more
Single 11.6" screen Dual screens — staining + coverslipping visibility

📦 What's Included

  • GHM-RF-III Stainer and Coverslipper unit

  • Staining racks (30-slide capacity each, 2 included)

  • Reagent containers (450ml each, 21 included, expandable to 23)

  • Coverslip magazine (holds 600 coverslips, 24×50mm)

  • Output racks (120-slide total capacity)

  • Macroslide rack (available on request)

  • Power cord (regional type supplied)

  • Quick start guide and protocol templates

  • 1-year warranty with technical support

View full details