Skip to product information
1 of 1

WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831

Global Healthcare Medical

GHM STD US Sexually Transmitted Disease Rapid Test (FIA) – Qualitative, 15-Minute, Whole Blood/Serum/Plasma

GHM STD US Sexually Transmitted Disease Rapid Test (FIA) – Qualitative, 15-Minute, Whole Blood/Serum/Plasma

Request a Quote / Contact for Price
Free worldwide shipping. Shipping included in the price.

SKU: GHM STD US
Brand: Global Healthcare Medical

Product Overview

Global Healthcare Medical GHM STD US Sexually Transmitted Disease Rapid Test (FIA) is a fluorescence immunoassay (FIA) designed for the qualitative and differential detection of multiple sexually transmitted disease pathogens from human whole blood, serum, or plasma samples. The test is used as an aid in the diagnosis of sexually transmitted infections (STIs), including HIV, syphilis, hepatitis B, and hepatitis C. Sexually transmitted infections remain a major global public health concern, and accurate, rapid, and cost-effective screening tests may be useful in clinical settings to support timely diagnosis and patient management.

The GHM STD US is intended for use with the FIA Analyzer (VIM01), a compact benchtop analyzer that utilizes fluorescence immunochromatography technology. The analyzer features auto calibration, barcode identification, and a built-in memory capacity of 50,000 results. The analyzer delivers reliable results in 10 ± 5 seconds after the test device is inserted.

The system is designed for professional use in clinical laboratories, hospitals, and clinics. The FIA analyzer operates with a small sample volume and provides fast, reliable results with simple operation.

This product is for in vitro diagnostic use only. For professional use only.

Key Features & Benefits

Multiplex STI Pathogen Detection – Comprehensive Differential Assessment

The GHM STD US delivers qualitative results for multiple sexually transmitted disease pathogens from a single specimen. This multiplex panel approach enables simultaneous detection and differentiation of bloodborne and bacterial STI pathogens, supporting timely clinical decision-making and appropriate patient management. These tests use pathogen-specific antibodies to detect proteins, carbohydrates, or lipid-carbohydrates present on the surface of STD pathogens, and have been extensively used for the diagnosis of STDs such as hepatitis B virus infection, chlamydial infection, and genital herpes.



Feature Benefit
Multiplex panel Simultaneous detection of multiple STI pathogens
Flexible specimen types Whole blood, serum, plasma
Intended use Aid in diagnosis of sexually transmitted infections
Test time 15 minutes
Clinical utility Supports screening and diagnosis of bloodborne and bacterial STIs
Flexible combination Multiple test items can be combined for customized panels

Comprehensive Test Menu – Broad Pathogen Coverage

The GHM STD US supports detection of a comprehensive panel of sexually transmitted disease pathogens, providing broad coverage for clinical sexual health testing needs.



Pathogen Category Test Items
HIV HIV 1/2 Antibodies (IgM and IgG)
Syphilis Treponema pallidum (TP) Antibodies (IgM and IgG)
Hepatitis B Hepatitis B Surface Antigen (HBsAg), Anti-HBs
Hepatitis C Anti-HCV Antibodies

Multiple panel configurations available. Contact Global Healthcare Medical for the complete test menu and panel customization options.

Sandwich Immunodetection Method – Fluorescence Immunoassay Principle

The GHM STD US uses a sandwich immunodetection method. When the sample is added to the sample well of the test device, fluorescence-labeled detector antibodies or antigens bind to target STI pathogen antigens or antibodies in the sample. As the sample mixture migrates on the nitrocellulose matrix of the test strip by capillary action, the complexes of detector and target are captured by immobilized capture antibodies or antigens at specific test lines on the strip. Thus, the more target antigen or antibody in the specimen, the more complexes accumulate on the test strip. The signal intensity of the fluorescent signal reflects the amount of target captured, and the FIA Analyzer displays the qualitative test result.



Feature Benefit
Sandwich immunodetection Reliable qualitative measurement principle
Fluorescence signal Clear positive/negative determination
Test strip technology Pathogen-specific antibodies or antigens at test lines; control line verification
Objective results Results interpreted automatically by analyzer
Small sample volume Minimizes specimen requirements

FIA Analyzer – Advanced Technical Platform

The GHM STD US is used with the FIA Analyzer (VIM01), a compact fluorescence immunoassay analyzer featuring auto calibration, barcode identification, and a large memory capacity.



Feature Benefit
Auto calibration Reduces manual calibration steps
Barcode identification 2D barcode scanning for test device identification
Code chip coding Automatic parameter recognition
Memory capacity 50,000 results storage
Connectivity Direct LIS/HIS connection
Display 3.5-inch LCD screen
Dimensions 173 × 210 × 75.8 mm
Weight 1.5 kg
Printer Built-in printer
Multi-parameter detection Analyzer can detect 30+ parameters

Wide Storage Temperature – No Cold Chain Required

The test kit is designed for convenient storage and transport, with a storage temperature range of 2 ~ 30°C, eliminating the need for cold chain logistics.



Specification Detail
Kit storage temperature 2 ~ 30°C
Operating temperature 18 ~ 25°C
Relative humidity 20 – 90%
Shelf life Up to 24 months

Simple Operation – Professional Laboratory Testing

The test procedure involves three simple steps: mix the sample with buffer, add the mixed specimen, and insert the device into the analyzer.



Step Action
1 Mix the sample with buffer
2 Add the mixed specimen
3 Insert device into the analyzer

Product Specifications



Specification Detail
Model / SKU GHM STD US
Product Type Sexually Transmitted Disease Rapid Test (FIA)
Specimen Whole blood, Serum, Plasma
Sample Volume 20 – 100 μL
Test Time 15 minutes
Measuring Range Negative / Positive
Operating Temperature 18 ~ 25°C
Storage Temperature 2 ~ 30°C
Shelf Life Up to 24 months
Analyzer Compatibility FIA Analyzer (VIM01)
Analyzer Display 3.5-inch LCD
Analyzer Dimensions 173 × 210 × 75.8 mm
Analyzer Weight 1.5 kg
Analyzer Memory 50,000 results
Analyzer Connectivity Direct LIS/HIS
Analyzer Test Time 10 ± 5 seconds
Analyzer Operation Temperature 5 ~ 40°C
Analyzer Storage Temperature -10 ~ 40°C
Relative Humidity 20 – 90%
Intended Use In vitro diagnostic use; professional use only
Package Options Kit format

Why Clinical Laboratories Choose Global Healthcare Medical



Consideration GHM STD US
Multiplex results Multiple pathogen detection from one specimen
Broad pathogen coverage HIV, syphilis, hepatitis B, and hepatitis C panels
Flexible specimen types Whole blood, serum, or plasma
Fast test time 15 minutes per test
Fast analyzer reading 10 ± 5 seconds per test
Auto calibration Reduces manual steps
Large memory 50,000 results storage
LIS/HIS connectivity Direct data integration
Convenient storage 2 ~ 30°C, no cold chain required
Simple operation Three-step test procedure
Multi-parameter platform Analyzer supports 30+ parameters
View full details