WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM STD US Sexually Transmitted Disease Rapid Test (FIA) – Qualitative, 15-Minute, Whole Blood/Serum/Plasma
GHM STD US Sexually Transmitted Disease Rapid Test (FIA) – Qualitative, 15-Minute, Whole Blood/Serum/Plasma
SKU: GHM STD US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM STD US Sexually Transmitted Disease Rapid Test (FIA) is a fluorescence immunoassay (FIA) designed for the qualitative and differential detection of multiple sexually transmitted disease pathogens from human whole blood, serum, or plasma samples. The test is used as an aid in the diagnosis of sexually transmitted infections (STIs), including HIV, syphilis, hepatitis B, and hepatitis C. Sexually transmitted infections remain a major global public health concern, and accurate, rapid, and cost-effective screening tests may be useful in clinical settings to support timely diagnosis and patient management.
The GHM STD US is intended for use with the FIA Analyzer (VIM01), a compact benchtop analyzer that utilizes fluorescence immunochromatography technology. The analyzer features auto calibration, barcode identification, and a built-in memory capacity of 50,000 results. The analyzer delivers reliable results in 10 ± 5 seconds after the test device is inserted.
The system is designed for professional use in clinical laboratories, hospitals, and clinics. The FIA analyzer operates with a small sample volume and provides fast, reliable results with simple operation.
This product is for in vitro diagnostic use only. For professional use only.
Key Features & Benefits
Multiplex STI Pathogen Detection – Comprehensive Differential Assessment
The GHM STD US delivers qualitative results for multiple sexually transmitted disease pathogens from a single specimen. This multiplex panel approach enables simultaneous detection and differentiation of bloodborne and bacterial STI pathogens, supporting timely clinical decision-making and appropriate patient management. These tests use pathogen-specific antibodies to detect proteins, carbohydrates, or lipid-carbohydrates present on the surface of STD pathogens, and have been extensively used for the diagnosis of STDs such as hepatitis B virus infection, chlamydial infection, and genital herpes.
| Feature | Benefit |
|---|---|
| Multiplex panel | Simultaneous detection of multiple STI pathogens |
| Flexible specimen types | Whole blood, serum, plasma |
| Intended use | Aid in diagnosis of sexually transmitted infections |
| Test time | 15 minutes |
| Clinical utility | Supports screening and diagnosis of bloodborne and bacterial STIs |
| Flexible combination | Multiple test items can be combined for customized panels |
Comprehensive Test Menu – Broad Pathogen Coverage
The GHM STD US supports detection of a comprehensive panel of sexually transmitted disease pathogens, providing broad coverage for clinical sexual health testing needs.
| Pathogen Category | Test Items |
|---|---|
| HIV | HIV 1/2 Antibodies (IgM and IgG) |
| Syphilis | Treponema pallidum (TP) Antibodies (IgM and IgG) |
| Hepatitis B | Hepatitis B Surface Antigen (HBsAg), Anti-HBs |
| Hepatitis C | Anti-HCV Antibodies |
Multiple panel configurations available. Contact Global Healthcare Medical for the complete test menu and panel customization options.
Sandwich Immunodetection Method – Fluorescence Immunoassay Principle
The GHM STD US uses a sandwich immunodetection method. When the sample is added to the sample well of the test device, fluorescence-labeled detector antibodies or antigens bind to target STI pathogen antigens or antibodies in the sample. As the sample mixture migrates on the nitrocellulose matrix of the test strip by capillary action, the complexes of detector and target are captured by immobilized capture antibodies or antigens at specific test lines on the strip. Thus, the more target antigen or antibody in the specimen, the more complexes accumulate on the test strip. The signal intensity of the fluorescent signal reflects the amount of target captured, and the FIA Analyzer displays the qualitative test result.
| Feature | Benefit |
|---|---|
| Sandwich immunodetection | Reliable qualitative measurement principle |
| Fluorescence signal | Clear positive/negative determination |
| Test strip technology | Pathogen-specific antibodies or antigens at test lines; control line verification |
| Objective results | Results interpreted automatically by analyzer |
| Small sample volume | Minimizes specimen requirements |
FIA Analyzer – Advanced Technical Platform
The GHM STD US is used with the FIA Analyzer (VIM01), a compact fluorescence immunoassay analyzer featuring auto calibration, barcode identification, and a large memory capacity.
| Feature | Benefit |
|---|---|
| Auto calibration | Reduces manual calibration steps |
| Barcode identification | 2D barcode scanning for test device identification |
| Code chip coding | Automatic parameter recognition |
| Memory capacity | 50,000 results storage |
| Connectivity | Direct LIS/HIS connection |
| Display | 3.5-inch LCD screen |
| Dimensions | 173 × 210 × 75.8 mm |
| Weight | 1.5 kg |
| Printer | Built-in printer |
| Multi-parameter detection | Analyzer can detect 30+ parameters |
Wide Storage Temperature – No Cold Chain Required
The test kit is designed for convenient storage and transport, with a storage temperature range of 2 ~ 30°C, eliminating the need for cold chain logistics.
| Specification | Detail |
|---|---|
| Kit storage temperature | 2 ~ 30°C |
| Operating temperature | 18 ~ 25°C |
| Relative humidity | 20 – 90% |
| Shelf life | Up to 24 months |
Simple Operation – Professional Laboratory Testing
The test procedure involves three simple steps: mix the sample with buffer, add the mixed specimen, and insert the device into the analyzer.
| Step | Action |
|---|---|
| 1 | Mix the sample with buffer |
| 2 | Add the mixed specimen |
| 3 | Insert device into the analyzer |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM STD US |
| Product Type | Sexually Transmitted Disease Rapid Test (FIA) |
| Specimen | Whole blood, Serum, Plasma |
| Sample Volume | 20 – 100 μL |
| Test Time | 15 minutes |
| Measuring Range | Negative / Positive |
| Operating Temperature | 18 ~ 25°C |
| Storage Temperature | 2 ~ 30°C |
| Shelf Life | Up to 24 months |
| Analyzer Compatibility | FIA Analyzer (VIM01) |
| Analyzer Display | 3.5-inch LCD |
| Analyzer Dimensions | 173 × 210 × 75.8 mm |
| Analyzer Weight | 1.5 kg |
| Analyzer Memory | 50,000 results |
| Analyzer Connectivity | Direct LIS/HIS |
| Analyzer Test Time | 10 ± 5 seconds |
| Analyzer Operation Temperature | 5 ~ 40°C |
| Analyzer Storage Temperature | -10 ~ 40°C |
| Relative Humidity | 20 – 90% |
| Intended Use | In vitro diagnostic use; professional use only |
| Package Options | Kit format |
Why Clinical Laboratories Choose Global Healthcare Medical
| Consideration | GHM STD US |
|---|---|
| Multiplex results | Multiple pathogen detection from one specimen |
| Broad pathogen coverage | HIV, syphilis, hepatitis B, and hepatitis C panels |
| Flexible specimen types | Whole blood, serum, or plasma |
| Fast test time | 15 minutes per test |
| Fast analyzer reading | 10 ± 5 seconds per test |
| Auto calibration | Reduces manual steps |
| Large memory | 50,000 results storage |
| LIS/HIS connectivity | Direct data integration |
| Convenient storage | 2 ~ 30°C, no cold chain required |
| Simple operation | Three-step test procedure |
| Multi-parameter platform | Analyzer supports 30+ parameters |