Skip to product information
1 of 1

WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831

Global Healthcare Medical

GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US – 96-Well Competitive ELISA for Quantitative Detection of Total T3 in Serum & Plasma (96T/Kit)

GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US – 96-Well Competitive ELISA for Quantitative Detection of Total T3 in Serum & Plasma (96T/Kit)

Regular price $32.00
Regular price Sale price $32.00
Sale Sold out
Free worldwide shipping. Shipping included in the price.

SKU: GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US
Brand: Global Healthcare Medical

Product Overview

Global Healthcare Medical GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the quantitative detection of total 3,5,3′-triiodo-thyronine (T3) in human serum and plasma specimens. T3 is the biologically active thyroid hormone, generated predominantly through peripheral deiodination of thyroxine (T4), and its measurement is central to laboratory research examining thyroid hormone signaling, metabolic regulation, and energy homeostasis. The kit employs a competitive ELISA principle: anti-T3 antibody is pre-coated onto the microwell strips, and a fixed amount of T3-HRP conjugate competes with sample T3 for limited antibody binding sites. Signal intensity at 450 nm is inversely proportional to the T3 concentration in the specimen—a higher sample T3 level produces a lower absorbance reading—enabling quantitative determination through standard curve interpolation.

The assay is configured for a 50 µL sample volume in published T3 competitive ELISA formats, with absorbance read at 450 nm using standard microplate spectrophotometers. Published specifications for T3 competitive ELISA report analytical sensitivity ranging from 0.047 ng/mL to 0.5 ng/mL, detection ranges spanning 0.156–10 ng/mL or 0.1–7.5 ng/mL, and assay times ranging from approximately 75 minutes to several hours, depending on the specific reagent configuration. The kit is supplied in a 96-test/box format with an 18-month shelf life, supporting routine laboratory workflows.

Intended Use: For laboratory research use only. This product is not intended for use in diagnostic procedures, not for donor screening, and not for confirmatory diagnostic testing. Results obtained with this assay are for research purposes and should not be used as the sole basis for clinical decision-making. Laboratory professionals should interpret results in conjunction with other research findings and applicable institutional protocols.

Key Features & Benefits

Competitive ELISA Principle

The assay utilizes a solid-phase competitive ELISA format. Anti-T3 antibody is immobilized on the 96-well microplate, and T3-HRP conjugate serves as the competitive detection reagent. When sample T3 is present, it competes with the T3-HRP conjugate for the limited number of antibody binding sites on the solid phase. After incubation and washing, unbound conjugate is removed, and TMB substrate is added. The resulting color development is measured at 450 nm, and the signal is inversely proportional to the T3 concentration in the sample. This competitive design is the established reference format for small-molecule hapten quantification such as total T3 in serum and plasma matrices.



Feature Benefit
Competitive ELISA format Established quantitative principle for total T3 measurement
Anti-T3 pre-coated microplate Targeted antibody presentation for competitive binding
T3-HRP conjugate detection Enzymatic signal generation for standard colorimetric reading
Inverse signal-to-concentration relationship Clear quantitative interpretation framework (higher T3 → lower OD)

Performance Consistent with Published T3 Competitive ELISA Benchmarks

Published specifications for T3 competitive ELISA kits report analytical sensitivity of 0.094 ng/mL and detection ranges of 0.156–10 ng/mL in high-sensitivity configurations; alternative published formats list sensitivity of 0.047 ng/mL, 0.078 ng/mL, or 0.1 ng/mL with linearity ranges of 0.1–7.5 ng/mL. Precision data for competitive T3 ELISA formats indicate intra-assay CV <8% and inter-assay CV <10% in high-performance configurations, with other published formats reporting intra-assay CV <10% and inter-assay CV <15%. Laboratories should qualify each lot against their own research acceptance criteria, as performance parameters vary by standard curve configuration, antibody pair selection, and conjugate formulation.



Feature Benefit
Analytical sensitivity down to 0.047 ng/mL (published benchmark) Supports detection of low-abundance T3 in research specimens
Intra-assay CV <8% (published benchmark, high-performance configuration) Within-run repeatability for batch processing
Inter-assay CV <10% (published benchmark, high-performance configuration) Between-run consistency across assay occasions
Competitive standard curve–based quantification Enables concentration interpolation across the calibrated range

Standardized 96-Well Workflow with 50 µL Sample Volume

The assay is formatted for standard 96-well microplate processing with a 50 µL sample volume in published T3 competitive ELISA configurations, accommodating serum and plasma (EDTA, heparin) matrices. Absorbance is measured at 450 nm, compatible with widely available ELISA readers and washers. Published T3 ELISA formats list assay times ranging from approximately 75 minutes to 2.5 hours, reflecting differences in incubation protocols and signal development systems.



Feature Benefit
96 tests/box Practical batch configuration for research workflows
50 µL serum/plasma sample volume (published configuration) Conserves specimen volume for multi-analyte thyroid research panels
450 nm reading Compatible with common microplate spectrophotometers
Competitive format compatible with standard wash protocols Aligns with routine ELISA equipment and workflows

18-Month Shelf Life

Reagent stability supports inventory planning and reduces replacement frequency in laboratory settings. Published T3 competitive ELISA product data list shelf-life configurations of 18 months at 2–8°C in some formats, while other published configurations report 6–12 months depending on storage conditions and reagent formulation.



Feature Benefit
18-month shelf life configuration Extended inventory stability for batch-oriented workflows
Consistent batch supply Supports repeatable longitudinal thyroid hormone research

Kit Contents & Pricing (EXW US Dollar)



Product Description Package Shelf Life Price/Kit (USD) CPT (USD/Test)
T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit 96 Tests/Box 18 Months $32.00 $0.3333

Cost per test: approximately $0.33, based on a 96-test kit configuration. The GHM configuration delivers a comparable competitive ELISA research format at a fraction of typical catalog pricing.

Product Specifications



Specification Detail
Model / SKU GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US
Product Type Enzyme-Linked Immunosorbent Assay (ELISA) Kit
Intended Use Quantitative detection of total 3,5,3′-triiodo-thyronine (T3) in human serum or plasma; for laboratory research use only; not for use in diagnostic procedures; not for donor screening
Assay Principle Competitive ELISA
Target Analyte 3,5,3′-Triiodo-thyronine (T3; total triiodothyronine; liothyronine)
Solid Phase Anti-T3 antibody pre-coated 96-well microplate
Detection System T3-HRP conjugate; TMB substrate; colorimetric signal at 450 nm
Specimen Types Human serum, plasma (EDTA, heparin)
Specimen Volume 50 µL/well (published configuration)
Package Size 96 Tests/Box
Shelf Life 18 Months
Reading Wavelength 450 nm
Analytical Sensitivity (published benchmark) 0.047–0.5 ng/mL (configuration-dependent); representative formats: 0.094 ng/mL, 0.1 ng/mL, 0.078 ng/mL
Precision (published benchmark) Intra-assay CV <8–10%; inter-assay CV <10–15% (configuration-dependent)
Detection Range (published benchmark) 0.156–10 ng/mL; alternative formats 0.1–7.5 ng/mL
Assay Time (published benchmark) Approximately 75 minutes to 2.5 hours (configuration-dependent)
Regulatory Status Manufactured under EN ISO 13485 certified quality management system

Why Laboratories Choose Global Healthcare Medical



Consideration GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US
Competitive ELISA principle Established quantitative format for total T3 measurement
Anti-T3 pre-coated microplate with T3-HRP detection Targeted competitive binding for small-molecule hapten quantification
Performance aligned with published benchmarks Sensitivity down to 0.047 ng/mL; CVs <8–10% in high-performance configurations
50 µL serum/plasma sample volume Specimen-conserving configuration for thyroid research panels
Cost-effective research screening $0.3333 per test; $32.00 per 96-test kit
18-month shelf life configuration Extended inventory stability
Standard 96-well format Compatible with routine ELISA readers and washers
ISO 13485 certified Quality management system compliance

About Global Healthcare Medical

Global Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM T3 3,5,3'-Triiodo-Thyronine ELISA Test Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.

Our focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.

View full details