Skip to product information
1 of 1

WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831

Global Healthcare Medical

GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-M. tuberculosis IgG in Serum & Plasma (96T/Kit)

GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-M. tuberculosis IgG in Serum & Plasma (96T/Kit)

Regular price $38.00
Regular price Sale price $38.00
Sale Sold out
Free worldwide shipping. Shipping included in the price.

SKU: GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US

Brand: Global Healthcare Medical

Product Overview

Global Healthcare Medical GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the semi-quantitative determination of immunoglobulin G (IgG)-class antibodies directed against Mycobacterium tuberculosis antigens in human serum and plasma specimens. M. tuberculosis is a slow-growing, acid-fast bacillus whose most distinctive feature is a lipid-rich, multi-layered cell envelope of unusual composition. This envelope comprises an inner plasma membrane, a peptidoglycan–arabinogalactan complex covalently linked to mycolic acids — very-long-chain α-branched fatty acids that form the characteristic outer bilayer — together with glycolipids and lipoglycans including lipoarabinomannan (LAM), phosphatidylinositol mannosides, and trehalose dimycolate. The cell surface also presents a defined set of secreted and cell-wall-associated protein antigens, among them the Antigen 85 complex (mycolyl transferases Ag85A/B/C), the ESAT-6 and CFP-10 proteins of the ESX-1 secretion system, and heat-shock proteins such as GroEL2. M. tuberculosis is studied within the broader field of mycobacterial cell envelope biology and serological characterisation of bacterial antigen recognition.

The IgG class is the most abundant immunoglobulin isotype in serum, accounting for approximately three quarters of total serum immunoglobulin, and it is the product of class switching and avidity maturation following antigen encounter. IgG circulates as a monomeric, bivalent molecule with two antigen-binding sites per molecule, and its neonatal Fc receptor–mediated recycling pathway gives it the longest circulatory half-life among the immunoglobulin classes. A key consideration for this antigen system is that protein antigens drive class switching and affinity maturation, whereas repetitive glycan and glycolipid epitopes elicit a largely T-independent response in which IgM predominates — so the IgG readout is particularly informative for the protein component of the mycobacterial antigen repertoire, namely the Antigen 85 complex, ESAT-6/CFP-10, and the heat-shock proteins. Measurement of anti-M. tuberculosis antibody IgG is used in research settings to characterise established humoral reactivity to mycobacterial protein antigens, study immunoglobulin class distribution across antibacterial antibody responses, and investigate protein antigen–antibody interaction profiles in immunological research models.

The kit employs a solid-phase ELISA principle with M. tuberculosis antigen immobilized on the solid phase and enzyme-conjugated anti-human IgG detection antibodies in the liquid phase. Results are evaluated against a cut-off value established from the assay calibrators, yielding a semi-quantitative interpretation expressed as a cut-off index. The assay is configured for a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours (depending on protocol configuration), with absorbance read at 450 nm using standard microplate ELISA equipment. The kit is supplied in a 96-test/box format with an 18-month shelf life.

Intended Use: For laboratory research use only. This product is not intended for use in diagnostic procedures, not for therapeutic use, and not for clinical decision-making. Results should be interpreted by qualified laboratory professionals in the context of research applications.

Key Features & Benefits

Solid-Phase ELISA for Anti-M. tuberculosis Antibody IgG Detection

The assay utilizes a solid-phase ELISA format in which M. tuberculosis antigen is coated onto the 96-well microplate and enzyme-conjugated anti-human IgG detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgG-class antibacterial reactivity in serum and plasma matrices. Because the detection conjugate is directed against the gamma heavy chain of human IgG, the readout is restricted to the IgG isotype and does not report total antimycobacterial immunoglobulin content — an important distinction when IgG and IgM classes are studied as separate analytes in a paired serological design.

Feature

Benefit

Solid-phase ELISA format

Established principle for antibacterial IgG detection

Anti-human IgG detection

IgG-isotype specific readout, not total immunoglobulin

Mycobacterial antigen coating

Presents envelope glycolipid and protein epitopes

Cut-off index evaluation

Standardised semi-quantitative interpretation

IgG Readout Targeted at the Protein Antigen Component

The mycobacterial antigen repertoire is not immunologically uniform. Repetitive glycan and glycolipid structures — lipoarabinomannan, arabinomannan, and mycolic acid–containing glycolipids — behave as T-independent type 2 antigens and elicit a largely IgM-dominated response. The protein antigens, by contrast, are processed and presented through the class II pathway and drive class switching with affinity maturation, so their corresponding antibodies are found predominantly in the IgG class. This configuration therefore provides an IgG readout that is selectively informative for the protein component of the antigen repertoire — the Antigen 85 complex, ESAT-6, CFP-10, and GroEL2 — and complements rather than duplicates an IgM determination performed on the same antigen preparation. Recognising this division is what allows the two isotype configurations to be used as a genuinely paired analytical design.

Feature

Benefit

Protein-antigen–focused IgG readout

Selectively informative for Ag85, ESAT-6, CFP-10, GroEL2

Class-switched, affinity-matured pool

Reflects a mature rather than early-phase response

Paired design with the IgM configuration

Complementary, non-duplicative isotype information

Whole-cell antigen coating

Preserves both glycan and protein epitopes

Monomeric Bivalent Binding with Defined Stoichiometry

IgG binds through a defined two-site stoichiometry per molecule, giving a quantifiable and highly reproducible interaction with the coated antigen across assay runs — an advantage for comparative work in which signal intensity must track antibody concentration consistently. This contrasts with the multivalent engagement characteristic of the pentameric IgM isotype on repetitive epitope arrays. IgG is the most extensively characterised isotype in antibacterial serology and the one with the largest body of comparable published data, which is why IgG results are commonly used as the reference axis when IgM data are interpreted alongside them.

Feature

Benefit

Monomeric bivalent IgG

Defined two-site stoichiometry; highly reproducible capture

Longest circulatory half-life

Stable, well-characterised analyte

Reference-axis positioning

Supports interpretation of paired IgM data

Native glycolipid and protein epitopes

Multi-component antigen repertoire retained

Performance Aligned with Published Antibacterial IgG ELISA Benchmarks

Published performance data for ELISA-format antibacterial IgG assays report sample volumes of 50–100 µL, a colorimetric microplate readout at 450 nm, and time to results of approximately 1–5 hours, with results expressed as a cut-off index derived from kit calibrators rather than a mass-concentration standard. Precision data for antibody-class ELISA formats of this type generally indicate intra-assay CV values below 10% and inter-assay CV values below 15%. Sample volumes of 50 µL are used in this configuration, and absorbance is read at 450 nm. Because the same assay format is commonly applied to paired IgM and IgG determinations, laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot, and should exercise independent judgment in interpreting cut-off index values in a research context.

Feature

Benefit

Cut-off index based semi-quantitative readout (published benchmark)

Standardised qualitative and semi-quantitative framework

Intra-assay CV <10%; inter-assay CV <15% (published benchmark)

Repeatability and reproducibility suitable for laboratory use

Arbitrary unit reporting

Consistent with established antibacterial ELISA practice

Standardized 96-Well Workflow with 50 µL Sample Volume

The assay is formatted for standard 96-well microplate processing with a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours. Absorbance is measured at 450 nm, aligning with widely available ELISA readers and washers.

Feature

Benefit

96 tests/box

Practical batch configuration for research workflows

50 µL sample volume

Standard ELISA sample requirement

450 nm reading

Compatible with common microplate spectrophotometers

~1.5–2.5 hour total incubation

Efficient turnaround for batch processing

18-Month Shelf Life

Extended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.

Feature

Benefit

18-month shelf life

Extended inventory stability

Consistent batch supply

Supports repeatable research workflows

Kit Contents & Pricing (EXW US Dollar)

Product Description

Package

Shelf Life

Price/Kit (USD)

CPT (USD/Test)

TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit

96 Tests/Box

18 Months

$38.00

$0.3958

Cost per test: approximately $0.40, based on a 96-test kit configuration.

Product Specifications

Specification

Detail

Model / SKU

GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US

Product Type

Enzyme-Linked Immunosorbent Assay (ELISA) Kit

Intended Use

Semi-quantitative determination of anti-M. tuberculosis antibody IgG in human serum or plasma; for laboratory research use only; not for use in diagnostic procedures; not for therapeutic use

Assay Principle

Solid-phase ELISA with anti-human IgG detection

Target Analyte

Anti-Mycobacterium tuberculosis antibody, immunoglobulin G (IgG) class

Immunoglobulin Class

IgG (gamma heavy chain specific; monomeric, bivalent)

Antigen

M. tuberculosis antigen (whole-cell preparation; protein and glycolipid epitopes)

Specimen Types

Human serum, plasma

Specimen Volume

50 µL/well

Package Size

96 Tests/Box

Shelf Life

18 Months

Reading Wavelength

450 nm

Total Incubation Time

Approximately 1.5–2.5 hours (protocol-dependent)

Precision (published benchmark)

Intra-assay CV <10%; inter-assay CV <15%

Result Interpretation

Cut-off index based semi-quantitative readout (published benchmark)

Calibration Format

Cut-off index referenced to kit calibrators (not mass-concentration calibrated)

Regulatory Status

Manufactured under EN ISO 13485 certified quality management system

Why Laboratories Choose Global Healthcare Medical

Consideration

GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US

Solid-phase ELISA with anti-human IgG detection

IgG-isotype specific readout, not total immunoglobulin

Protein-antigen–focused IgG readout

Selectively informative for Ag85, ESAT-6, CFP-10, GroEL2

Monomeric bivalent binding

Defined two-site stoichiometry; reproducible capture

Paired design with the IgM configuration

Complementary, non-duplicative isotype information

Performance aligned with published antibacterial IgG ELISA benchmarks

Cut-off index based; CV <10%/<15%

Cost-effective research serology

$0.3958 per test; $38.00 per 96-test kit

18-month shelf life

Extended inventory stability

Standard 96-well format

Compatible with routine ELISA equipment

ISO 13485 certified

Quality management system compliance

About Global Healthcare Medical

Global Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.

Our focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.

View full details