Contact via WhatsApp: +81 9022195237
Global Healthcare Medical
GHM834 Anesthesia Machine Basic Version with WX350 Breathing Circuit #
GHM834 Anesthesia Machine Basic Version with WX350 Breathing Circuit #
Couldn't load pickup availability
The GHM834 Anesthesia Machine combines electronically controlled, pneumatically driven technology with a human-centered design. Engineered for comfort, safety, and ease of operation, this basic version is equipped with the WX500 Breathing Circuit, delivering reliable anesthesia support for adult and pediatric patients.
Key Features:
-
Electronically Controlled, Pneumatically Driven
Offers precise control and smooth performance, ensuring consistent ventilation and anesthesia delivery across a variety of clinical scenarios. -
WX500 Breathing Circuit
Integrated with the WX500 Breathing Circuit, designed for optimized gas delivery, enhanced patient-ventilator interaction, and improved workflow efficiency during anesthesia procedures. -
Versatile Patient Compatibility
Suitable for adults and children, making it a flexible solution for diverse surgical and procedural needs. -
Multiple Ventilation Modes
Supports VCV, SIMV, PCV, MAN, and Standby modes, providing flexibility to accommodate different patient conditions and clinical preferences. -
Wide Parameter Ranges
-
Tidal Volume: 0, 20–1500 mL
-
Respiratory Rate: 0, 1–100 bpm
-
I:E Ratio: 1:10 – 10:1
-
PEEP: OFF, 4–30 cmH₂O
-
Pressure Control: 5–70 cmH₂O
-
-
Comprehensive Monitoring
Real-time monitoring of tidal volume, minute ventilation (0–30 L/min), respiratory rate, FiO₂ (18–100 vol%), ETCO₂ (0–13 vol%), and PEEP (0–70 cmH₂O) for complete visibility of patient status. -
Optional Connectivity
Capable of connecting external ETCO₂ monitoring and Anesthesia Gas Scavenging System (AGSS) for enhanced safety and expanded functionality. -
Waveform & Loop Displays
Visualize pressure-time and flow-time waveforms, as well as pressure-volume and flow-volume loops, to assist in accurate clinical assessment. -
Reliable Power Backup
In the event of AC power failure, the system automatically switches to battery power with an audible and visual alarm, ensuring uninterrupted operation. -
Comprehensive Safety Alarms
Includes apnea alarm (10–40 seconds), low battery alarm (≥15 minutes), run-out battery alarm (≥3 minutes), and alarm mute timing (≤120 seconds) to maintain patient safety at all times. -
Vaporizer Compatibility
Supports multiple vaporizer types including Enflurane, Isoflurane, Sevoflurane, and Halothane to accommodate various anesthetic agents. -
Flexible Gas Sources
Compatible with O₂, N₂O, and AIR gas sources for versatile clinical application.
Share