WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
Heyer Aeon7200A High-End Anesthesia Machine
Heyer Aeon7200A High-End Anesthesia Machine
The Aeon7200A High-End is the full-capability configuration of the Aeon7200A continuous-flow anesthesia workstation, designed for operating room anesthesia and respiratory support where comprehensive ventilation modes, integrated monitoring, and upgrade readiness are operational priorities. It is intended for infants, children, and adults, including patients weighing over 3 kg as referenced in regulatory documentation.
Where the Standard configuration centers on core anesthesia delivery, the High-End platform exposes the complete ventilation mode set — IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP/PS — alongside readiness for anesthetic gas monitoring (AGM), CO₂ monitoring (mainstream or side-stream), anesthetic gas scavenging (AGSS), and suction system integration. The 8.4-inch color touchscreen, alloy breathing system with 1.8 L canister, 20 mL minimum tidal volume, dynamic tidal volume compensation, and 2-hour integrated battery form the shared foundation.
The platform is CE marked and holds valid registrations including MDA Malaysia (GC2859922-101109, 2022–2027) and China NMPA (国械注准20163080322) for the Aeon7200A series. Configuration, modules, vaporizers, and local registration may vary; confirm the final specification with your supplier.
Key Features & Benefits
Complete Ventilation Mode Set: IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP/PS
The High-End configuration exposes the full Aeon7200A mode ceiling:
-
IPPV (Intermittent Positive Pressure Ventilation)
-
PCV (Pressure Controlled Ventilation)
-
SIMV-VC (Synchronized Intermittent Mandatory Ventilation — Volume Controlled)
-
SIMV-PC (Synchronized Intermittent Mandatory Ventilation — Pressure Controlled)
-
CPAP / PS (Continuous Positive Airway Pressure / Pressure Support)
A quick button switches between manual and automatic ventilation, supporting workflow transitions during induction, maintenance, and emergence. The mode set is intended to match different anesthesia ventilation requirements across infant, pediatric, and adult patients. Mode selection and parameter settings should always be performed by trained clinical personnel according to local protocols.
Upgrade-Ready Monitoring: AGM, CO₂ (Mainstream or Side-Stream), and CO₂ Bypass
The High-End platform is configured for optional monitoring expansion:
-
Multiple Anesthetic Gas Monitoring (AGM) — referenced as helping clinicians conveniently control gas concentration
-
CO₂ monitoring — available in mainstream or side-stream configurations
These options are intended to support informed anesthetic management by making gas concentration data available at the point of care. Monitoring module selection and configuration should follow local protocols and the configured accessory set.
Comprehensive Safety Architecture
The High-End platform carries the full Aeon7200A safety stack:
-
Power-on self-test — can be skipped in emergency situations and completed later
-
Automatic power-off 10 seconds after switch-off in case of accidental operation
-
Safety valve referenced at ≤10 kPa in distributor documentation
These features are intended to support safe anesthesia delivery and are referenced across platform documentation.
8.4-Inch Color Touchscreen with Color-Coded Loops, Waveforms, and Parameters
The 8.4-inch LCD color touchscreen provides simultaneous monitoring of loops, waveforms, set parameters, and monitored parameters with color-coded displays for efficient interpretation. Waveforms referenced include P-T, F-T, and V-T; monitored values include Paw, Ppeak, Pplat, Pmean, MV, Vt, breath rate, FiO₂, and compliance. Spirometry loops are referenced as supporting interpretation of ventilation effectiveness.
Accurate Tidal Volume Delivery: 20 mL Minimum, Dynamic Compensation
The platform supports tidal volume from 20 mL to 1500 mL, with a minimum 20 mL referenced as suitable for infant, pediatric, and adult patients. The dynamic compensation system for tidal volume and advanced electromagnetic valve are referenced as ensuring accurate tidal volume and compensation. This supports consistent volume delivery across the patient range.
Alloy Breathing System with 1.8 L Canister
The alloy breathing system features a 1.8 L canister referenced as meeting long operating time requirements. The alloy construction supports durability and repeated use workflows in operating room environments.
Integrated 2-Hour Battery and Pneumatic Drive
The Aeon7200A is pneumatically driven and electronically controlled, with an integrated battery providing 2 hours of backup (DC 24V, minimum 120 minutes) referenced across technical sources. This supports continuity during power interruption and intra-hospital movement where configured.
Optional AGSS and Suction System for Operating Room Integration
The High-End configuration is ready for optional anesthetic gas scavenging (AGSS) — referenced as supporting passive and active systems — and an optional suction system. AGSS is referenced as protecting the device while reducing air pollution in the operating room. These upgrades support integration into complete operating room workflows.
Vaporizer Flexibility: Selectatec-Compatible, Up to 2 Units
The workstation supports up to 2 vaporizers with Selectatec-compatible mounting; agent types referenced include Halothane, Enflurane, Isoflurane, and Sevoflurane. Vaporizer models referenced in regulatory listings include VP300 and VP500.
Technical Specifications
Note: Battery runtime is referenced as minimum 90 minutes in some Aeonmed technical listings and minimum 120 minutes in others; the 2-hour (120-minute) figure is used here based on the Schiller India and HTSY listings. Dimensions of 1356×620×849 mm are drawn from HTSY Medical’s Aeon7200A-specific table; Aeonmed’s own ecvery listing cites 824×1382×680 mm for the same model platform — confirm the exact configured dimensions and weight for your unit with the supplier before publishing.
Why Choose the Aeon7200A High-End?
| Clinical or Operational Need | Aeon7200A High-End Solution |
|---|---|
| Need the complete Aeon7200A ventilation mode ceiling | IPPV, PCV, SIMV-VC, SIMV-PC, CPAP/PS, with Manual/Auto quick switch |
| Need ready access to anesthetic gas concentration data | Optional AGM and CO₂ monitoring (mainstream or side-stream) |
| Need scavenging and suction integration | Optional AGSS (passive/active) and optional suction system |
| Need infant-to-adult tidal volume coverage | 20–1500 mL range with 20 mL minimum |
| Need accurate volume delivery | Dynamic tidal volume compensation and advanced electromagnetic valve |
| Need a clear, color-coded interface | 8.4-inch color touchscreen with loops, waveforms, and parameters in color |
| Need comprehensive safety features | N₂O cut-off, O₂ ratio control, O₂ concentration monitoring, skippable self-test |
| Need battery backup for continuity | Integrated 2-hour battery (DC 24V, min. 120 min) |
| Need vaporizer flexibility | Selectatec-compatible, up to 2 vaporizers |
