Skip to product information
1 of 3

WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831

Global Healthcare Medical

Heyer Aeon7200A High-End Anesthesia Machine

Heyer Aeon7200A High-End Anesthesia Machine

Regular price $10,999.00
Regular price $14,500.00 Sale price $10,999.00
Sale Sold out
Free worldwide shipping. Shipping included in the price.

The Aeon7200A High-End is the full-capability configuration of the Aeon7200A continuous-flow anesthesia workstation, designed for operating room anesthesia and respiratory support where comprehensive ventilation modes, integrated monitoring, and upgrade readiness are operational priorities. It is intended for infants, children, and adults, including patients weighing over 3 kg as referenced in regulatory documentation.

Where the Standard configuration centers on core anesthesia delivery, the High-End platform exposes the complete ventilation mode set — IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP/PS — alongside readiness for anesthetic gas monitoring (AGM), CO₂ monitoring (mainstream or side-stream), anesthetic gas scavenging (AGSS), and suction system integration. The 8.4-inch color touchscreen, alloy breathing system with 1.8 L canister, 20 mL minimum tidal volume, dynamic tidal volume compensation, and 2-hour integrated battery form the shared foundation.

The platform is CE marked and holds valid registrations including MDA Malaysia (GC2859922-101109, 2022–2027) and China NMPA (国械注准20163080322) for the Aeon7200A series. Configuration, modules, vaporizers, and local registration may vary; confirm the final specification with your supplier.

Key Features & Benefits

Complete Ventilation Mode Set: IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP/PS

The High-End configuration exposes the full Aeon7200A mode ceiling:

  • IPPV (Intermittent Positive Pressure Ventilation)

  • PCV (Pressure Controlled Ventilation)

  • SIMV-VC (Synchronized Intermittent Mandatory Ventilation — Volume Controlled)

  • SIMV-PC (Synchronized Intermittent Mandatory Ventilation — Pressure Controlled)

  • CPAP / PS (Continuous Positive Airway Pressure / Pressure Support)

A quick button switches between manual and automatic ventilation, supporting workflow transitions during induction, maintenance, and emergence. The mode set is intended to match different anesthesia ventilation requirements across infant, pediatric, and adult patients. Mode selection and parameter settings should always be performed by trained clinical personnel according to local protocols.

Upgrade-Ready Monitoring: AGM, CO₂ (Mainstream or Side-Stream), and CO₂ Bypass

The High-End platform is configured for optional monitoring expansion:

  • Multiple Anesthetic Gas Monitoring (AGM) — referenced as helping clinicians conveniently control gas concentration

  • CO₂ monitoring — available in mainstream or side-stream configurations

  • CO₂ bypass function — referenced as an optional function

These options are intended to support informed anesthetic management by making gas concentration data available at the point of care. Monitoring module selection and configuration should follow local protocols and the configured accessory set.

Comprehensive Safety Architecture

The High-End platform carries the full Aeon7200A safety stack:

  • Power-on self-test — can be skipped in emergency situations and completed later

  • N₂O cut-off valve and oxygen ratio control valve

  • Oxygen concentration monitoring system

  • Automatic power-off 10 seconds after switch-off in case of accidental operation

  • Safety valve referenced at ≤10 kPa in distributor documentation

These features are intended to support safe anesthesia delivery and are referenced across platform documentation.

8.4-Inch Color Touchscreen with Color-Coded Loops, Waveforms, and Parameters

The 8.4-inch LCD color touchscreen provides simultaneous monitoring of loops, waveforms, set parameters, and monitored parameters with color-coded displays for efficient interpretation. Waveforms referenced include P-T, F-T, and V-T; monitored values include Paw, Ppeak, Pplat, Pmean, MV, Vt, breath rate, FiO₂, and compliance. Spirometry loops are referenced as supporting interpretation of ventilation effectiveness.

Accurate Tidal Volume Delivery: 20 mL Minimum, Dynamic Compensation

The platform supports tidal volume from 20 mL to 1500 mL, with a minimum 20 mL referenced as suitable for infant, pediatric, and adult patients. The dynamic compensation system for tidal volume and advanced electromagnetic valve are referenced as ensuring accurate tidal volume and compensation. This supports consistent volume delivery across the patient range.

Alloy Breathing System with 1.8 L Canister

The alloy breathing system features a 1.8 L canister referenced as meeting long operating time requirements. The alloy construction supports durability and repeated use workflows in operating room environments.

Integrated 2-Hour Battery and Pneumatic Drive

The Aeon7200A is pneumatically driven and electronically controlled, with an integrated battery providing 2 hours of backup (DC 24V, minimum 120 minutes) referenced across technical sources. This supports continuity during power interruption and intra-hospital movement where configured.

Optional AGSS and Suction System for Operating Room Integration

The High-End configuration is ready for optional anesthetic gas scavenging (AGSS) — referenced as supporting passive and active systems — and an optional suction system. AGSS is referenced as protecting the device while reducing air pollution in the operating room. These upgrades support integration into complete operating room workflows.

Vaporizer Flexibility: Selectatec-Compatible, Up to 2 Units

The workstation supports up to 2 vaporizers with Selectatec-compatible mounting; agent types referenced include Halothane, Enflurane, Isoflurane, and Sevoflurane. Vaporizer models referenced in regulatory listings include VP300 and VP500.

Technical Specifications



Specification Detail
Device Type Continuous-flow anesthesia workstation
Model Aeon7200A (High-End configuration)
Manufacturer Beijing Aeonmed Co., Ltd.
Brand Heyer (post-2019 Aeonmed–HEYER merger)
Patient Range Infants, children, and adults; >3 kg referenced in NMPA registration documentation
Drive / Control Pneumatically driven and electronically controlled
Working Modes Closed, semi-closed, semi-open
Ventilation Modes IPPV, PCV, SIMV-VC, SIMV-PC, CPAP/PS; Manual/Auto quick switch
Tidal Volume (VT) 20–1500 mL (minimum 20 mL referenced for infant/pediatric suitability)
Ventilation Frequency 4–100 bpm
I:E Ratio 2:1–1:8
Pressure Control 5–60 cmH₂O
PEEP 0–20 cmH₂O
Inspiratory Plateau 0–50% Ti
Trigger Sensitivity 2–30 L/min
High / Low Pressure Limits 21–80 cmH₂O / 0–20 cmH₂O
Display 8.4-inch LCD color touchscreen; color-coded loops, waveforms, and parameters
Flowmeters Double-tube mechanical flowmeters for each gas (2-gas configuration); O₂: 0–1 / 1–10 L/min; N₂O: 0–1 / 1–10 L/min
Breathing System Alloy breathing system with 1.8 L canister
Gas Supply O₂, N₂O: 0.28–0.6 MPa
O₂ Flush 35–75 L/min
Safety Features Power-on self-test (skippable); N₂O cut-off valve; O₂ ratio control; O₂ concentration monitoring; safety valve ≤10 kPa
Optional Monitoring AGM; CO₂ (mainstream or side-stream); CO₂ bypass
Optional Upgrades AGSS (passive/active); Suction system
Vaporizers Up to 2, Selectatec-compatible; VP300/VP500 referenced; Halothane, Enflurane, Isoflurane, Sevoflurane
Battery Integrated, 2 hours; DC 24V, minimum 120 minutes
Power Supply AC 100–240 V, 50/60 Hz
Dimensions (H×W×D) 1356 × 620 × 849 mm
Weight 110 kg (basic model)
Operating Temperature 10–40°C
Storage Temperature -20–55°C
Operating / Storage Humidity ≤80% / ≤93% (non-condensing)
Regulatory Reference CE marked; MDA Malaysia GC2859922-101109 (2022–2027); China NMPA 国械注准20163080322 (Aeon7200A series)

Note: Battery runtime is referenced as minimum 90 minutes in some Aeonmed technical listings and minimum 120 minutes in others; the 2-hour (120-minute) figure is used here based on the Schiller India and HTSY listings. Dimensions of 1356×620×849 mm are drawn from HTSY Medical’s Aeon7200A-specific table; Aeonmed’s own ecvery listing cites 824×1382×680 mm for the same model platform — confirm the exact configured dimensions and weight for your unit with the supplier before publishing.

Why Choose the Aeon7200A High-End?



Clinical or Operational Need Aeon7200A High-End Solution
Need the complete Aeon7200A ventilation mode ceiling IPPV, PCV, SIMV-VC, SIMV-PC, CPAP/PS, with Manual/Auto quick switch
Need ready access to anesthetic gas concentration data Optional AGM and CO₂ monitoring (mainstream or side-stream)
Need scavenging and suction integration Optional AGSS (passive/active) and optional suction system
Need infant-to-adult tidal volume coverage 20–1500 mL range with 20 mL minimum
Need accurate volume delivery Dynamic tidal volume compensation and advanced electromagnetic valve
Need a clear, color-coded interface 8.4-inch color touchscreen with loops, waveforms, and parameters in color
Need comprehensive safety features N₂O cut-off, O₂ ratio control, O₂ concentration monitoring, skippable self-test
Need battery backup for continuity Integrated 2-hour battery (DC 24V, min. 120 min)
Need vaporizer flexibility Selectatec-compatible, up to 2 vaporizers
View full details