Global Healthcare Medical
Heyer Aeon7200A Standard Anesthesia Machine
Heyer Aeon7200A Standard Anesthesia Machine
The Aeon7200A Standard is a continuous-flow anesthesia workstation configured with two gas sources and double-tube mechanical flowmeters for each gas, designed for inhalation anesthesia and respiratory support in hospital operating rooms. It is intended for use by licensed clinicians and is suitable for infants, children, and adults, including patients weighing over 3 kg as referenced in regulatory documentation.
The system integrates quantitative anesthetic agent delivery (N₂O, Isoflurane, Sevoflurane, Enflurane, Desflurane, and others), oxygen delivery (≥21%), and ventilation support into a single pneumatically driven, electronically controlled workstation. The integrated breathing system delivers a mixture of O₂, N₂O, AIR, and anesthetic agents, with closed, semi-closed, and semi-open working modes.
The Standard configuration includes an 8.4-inch color LCD touchscreen, IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP/PS ventilation modes, a minimum tidal volume of 20 mL supporting infant and pediatric patients, an alloy breathing system with a 1.8 L canister, and an integrated battery providing 2 hours of backup. It is CE marked and carries a valid MDA Malaysia registration (GC2859922-101109, 2022–2027) .
Key Features & Benefits
Standard 2-Gas Configuration with Double-Tube Flowmeters
The Standard model is configured for two gas sources with double-tube mechanical flowmeters for each gas, supporting precise fresh gas delivery during low-flow and routine anesthesia workflows. The flowmeter configuration supports O₂ and N₂O delivery, with AIR integration referenced in the breathing system description.
Continuous-Flow Anesthesia for Infants, Children, and Adults (≥3 kg)
The Aeon7200A is a continuous-flow anesthetic system offering manual or automatic ventilation, easily adjustable fresh gas delivery, and anesthetic agent delivery. Regulatory documentation describes suitability for infants, children, and adults, with intended use for patients over 3 kg. The minimum tidal volume of 20 mL supports pediatric and infant ventilation requirements within this range.
Ventilation Modes: IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP/PS
The Standard configuration supports:
-
IPPV (Intermittent Positive Pressure Ventilation)
-
PCV (Pressure Controlled Ventilation)
-
SIMV-VC (Synchronized Intermittent Mandatory Ventilation — Volume Controlled)
-
SIMV-PC (Synchronized Intermittent Mandatory Ventilation — Pressure Controlled)
-
CPAP / PS (Continuous Positive Airway Pressure / Pressure Support)
A quick button allows switching between manual and automatic ventilation modes. These modes are intended to meet different anesthesia ventilation requirements. Mode selection and parameter settings should always be performed by trained clinical personnel according to local protocols.
8.4-Inch Color Touchscreen with Comprehensive Monitoring
The 8.4-inch LCD color touchscreen provides simultaneous monitoring of loops, waveforms, set parameters, and monitored parameters with color-coded displays for efficient interpretation. The interface is referenced as supporting faster and more efficient operation.
Accurate Tidal Volume Delivery with Dynamic Compensation
The Aeon7200A includes a dynamic compensation system for tidal volume and an advanced electromagnetic valve referenced as ensuring accurate tidal volume and compensation. This design supports consistent volume delivery across the 20–1500 mL tidal volume range.
Alloy Breathing System with 1.8 L Canister
The alloy breathing system features a 1.8 L canister referenced as meeting long operating time requirements. The alloy construction supports durability and repeated use workflows in operating room environments.
Integrated Safety System
The Standard configuration includes multiple safety features:
-
Power-on self-test — can be skipped in emergency situations and carried out later
-
N₂O cut-off valve
-
Oxygen ratio control valve
-
Oxygen concentration monitoring system
-
Automatic power-off 10 seconds after switch-off in case of accidental operation
-
Safety valve (≤10 kPa referenced in distributor documentation)
These features are intended to support safe anesthesia delivery and are referenced in product documentation.
Integrated Battery Backup for 2 Hours
The system includes an integrated battery providing 2 hours of backup power (DC 24V, minimum 120 minutes referenced across technical sources). This supports continuity during power interruption and intra-hospital transport where configured.
Vaporizer Flexibility: Selectatec-Compatible, Up to 2 Units
The workstation supports up to 2 vaporizers with Selectatec-compatible mounting. Agent types referenced include Halothane, Enflurane, Isoflurane, and Sevoflurane. Vaporizer models referenced in regulatory listings include the VP300.
Optional Upgrades: AGM, CO₂ Monitoring, AGSS, and Suction
Optional configurations referenced in distributor documentation include:
-
Multiple anesthetic gas monitoring (AGM) or CO₂ monitoring (mainstream or side-stream)
-
Scavenging system (AGSS) supporting passive and active systems
-
Suction system
-
Vaporizers for all anesthetic agents with various filling options
Technical Specifications
| Specification | Detail |
|---|---|
| Device Type | Continuous-flow anesthesia workstation |
| Model | Aeon7200A (Standard configuration: 2-gas, double-tube flowmeters) |
| Manufacturer | Beijing Aeonmed Co., Ltd. |
| Brand | Heyer (post-2019 Aeonmed–HEYER merger) |
| Patient Range | Infants, children, and adults; >3 kg referenced in regulatory documentation |
| Drive / Control | Pneumatically driven and electronically controlled |
| Working Modes | Closed, semi-closed, semi-open |
| Ventilation Modes | IPPV, PCV, SIMV-VC, SIMV-PC, CPAP/PS; Manual/Auto quick switch |
| Tidal Volume (VT) | 20–1500 mL (minimum 20 mL referenced for infant/pediatric suitability) |
| Ventilation Frequency | 2–100 bpm (distributor listing); confirm configured range with supplier |
| Inspiratory Pressure | 5–70 cmH₂O (distributor listing); confirm with supplier |
| Display | 8.4-inch LCD color touchscreen; color-coded loops, waveforms, and parameters |
| Flowmeters | Double-tube mechanical flowmeters for each gas; 2-gas configuration |
| Breathing System | Alloy breathing system with 1.8 L canister |
| Gas Supply | O₂, N₂O: 0.28–0.6 MPa |
| Safety Features | Power-on self-test (skippable); N₂O cut-off valve; O₂ ratio control; O₂ concentration monitoring; safety valve ≤10 kPa |
| Vaporizers | Up to 2, Selectatec-compatible; VP300 referenced |
| Battery | DC 24V, minimum 120 minutes (2 hours) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (H×W×D) | 1356 × 620 × 849 mm (HTSY listing); 1540 × 780 × 700 mm referenced in ANMAT documentation for Aeon7200 — confirm exact dimensions for your configured unit |
| Weight | 110 kg (basic model) |
| Operating Temperature | 10–40°C |
| Storage Temperature | -20–55°C |
| Operating Humidity | ≤80% (non-condensing) |
| Storage Humidity | ≤93% (non-condensing) |
| Regulatory Reference | CE marked (referenced in distributor documentation); MDA Malaysia registration GC2859922-101109, valid 15/08/2022–14/08/2027 |
Note: Tidal volume, frequency, and dimensions vary slightly across source documents. The 20–1500 mL range is consistent across multiple distributor listings for the Aeon7200A. Dimensions of 1356×620×849 mm are drawn from an Aeon7200A-specific technical listing; 1540×780×700 mm appears in ANMAT documentation for the Aeon7200 platform. Confirm the exact configured dimensions and weight for your unit with the supplier before publishing.
Why Choose the Aeon7200A Standard?
| Clinical or Operational Need | Aeon7200A Standard Solution |
|---|---|
| Need a standard continuous-flow anesthesia workstation | 2-gas, double-tube flowmeter configuration with integrated breathing system |
| Need infant-to-adult patient coverage | Infants, children, and adults; >3 kg; minimum 20 mL tidal volume |
| Need multiple ventilation modes | IPPV, PCV, SIMV-VC, SIMV-PC, CPAP/PS |
| Need accurate volume delivery | Dynamic tidal volume compensation and advanced electromagnetic valve |
| Need a clear, efficient interface | 8.4-inch color touchscreen with color-coded loops, waveforms, and parameters |
| Need safety features for anesthesia delivery | N₂O cut-off valve, O₂ ratio control, O₂ concentration monitoring, self-test |
| Need battery backup | Integrated 2-hour battery (DC 24V, min. 120 min) |
| Need vaporizer flexibility | Selectatec-compatible, up to 2 vaporizers |
| Need optional monitoring and scavenging | Optional AGM, CO₂ monitoring, AGSS, suction |