WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
Heyer Aeon8800A Anesthesia Machine
Heyer Aeon8800A Anesthesia Machine
The Aeon8800A is a high-level anesthesia workstation engineered around lung-protective ventilation, precise low-tidal-volume delivery, and intelligent fresh-gas management for infants, children, and adult patients. It combines a magnesium-aluminium alloy integrated breathing circuit with 35°C constant-temperature heating, ultra-light 0.7 g ceramic inspiratory and expiratory valves referenced as suitable for patients with weak respiratory effort such as infants, and a minimum tidal volume of 10 mL in volume control mode.
The platform supports ventilator-level ventilation modes including VCV, PCV, SIMV, PS + Apnea ventilation, PCV-VG, BIVENT, SIMV-VG, and SIMV-PC, alongside a digital flowmeter with ECO-Optimizer referenced as supporting safe low-flow and minimal-flow anesthesia while reducing anesthetic agent and medical gas waste. A Driven Gas Auto-Switch function first uses compressed air as drive gas to reduce oxygen consumption.
Clinical tools include Stress Index (SI) monitoring for individualized PEEP titration, a Static PV loop tool for PEEP and tidal volume setting, two recruitment maneuver types (stepwise PEEP and sustained inflation), Driving Pressure (DP) monitoring, and cardiopulmonary bypass (CBP) modes. A 15.1-inch TFT color touchscreen provides waveform and loop display, with electronic flowmeter control for O₂, N₂O, and air.
The Aeon8800A is CE marked, meeting referenced EU clinical requirements. Optional configurations include VP300/VP500 vaporizers, a spotlight, and an auxiliary folding table. Confirm the final configuration, vaporizer models, and local registration with your supplier.
Key Features & Benefits
Lung-Protective Ventilation Toolkit: 10 mL Minimum VT, PCV-VG, BIVENT, SI, PV Loop, and Recruitment Maneuvers
The Aeon8800A integrates a lung-protective ventilation toolkit referenced as supporting reduction of postoperative pulmonary complications (PPCs):
-
Minimum tidal volume of 10 mL in volume control mode, supporting precise low-tidal-volume ventilation
-
PCV-VG and BIVENT modes for individualized low-tidal-volume delivery
-
Stress Index (SI) monitoring for individualized PEEP titration
-
Static PV loop tool to guide PEEP and tidal volume setting
-
Two recruitment maneuver types: stepwise PEEP and sustained inflation
-
Driving Pressure (DP) monitoring (range 0–100 cmH₂O) referenced to guide ventilation parameter adjustment
These tools are intended to support lung-protective ventilation strategies and are referenced as clinical support functions, not as independent outcome guarantees.
Magnesium-Aluminium Alloy Integrated Breathing Circuit with 35°C Heating
The characteristic breathing circuit is made of alloy, referenced as corrosion-resistant and able to withstand repeated high-temperature and high-pressure sterilization (up to 134°C). The integrated heating system leverages the alloy’s better thermal conductivity to prevent condensation and support patient comfort. The circuit includes a CO₂ bypass function, and the APL valve with fast-release pressure supports precisely adjustable upper pressure limits.
Ultra-Light 0.7 g Ceramic Valves for Infant and Pediatric Sensitivity
The breathing circuit is equipped with ceramic inspiratory and expiratory valves weighing as little as 0.7 g, referenced as suitable for patients with weak respiratory effort, such as infants and young children. This design supports the platform’s infant-to-adult patient coverage.
Digital Flowmeter with ECO-Optimizer and Driven Gas Auto-Switch
The Digital Flowmeter makes fresh gas flow setting easier and more precise, with electronic monitoring of O₂, N₂O, and air alongside mechanical flowmeter total gas volume monitoring. The ECO-Optimizer indicates the recommended fresh gas flow setting according to set values and patient needs, supporting safe low-flow and minimal-flow anesthesia while reducing anesthetic agent and medical gas waste. The Driven Gas Auto-Switch first uses compressed air as drive gas to reduce oxygen consumption.
Ventilator-Level Ventilation Modes: VCV, PCV, SIMV, PS + Apnea, PCV-VG, BIVENT
The Aeon8800A supports ventilator-level ventilation modes referenced as suitable for various clinical situations, covering infants through adults:
-
VCV (Volume Control Ventilation)
-
PCV (Pressure Control Ventilation)
-
SIMV (Synchronized Intermittent Mandatory Ventilation)
-
PS + Apnea ventilation
-
PCV-VG (Pressure Control Ventilation — Volume Guaranteed)
-
BIVENT
A one-key operation supports switching between manual and mechanical ventilation.
15.1-Inch TFT Color Touchscreen with Comprehensive Monitoring
The 15.1-inch TFT LCD color screen provides highlighted display of main ventilation parameters, monitored data, and message alerts simultaneously. Graph display includes P-T and F-T waveforms and P-V and F-V loops, with a waveform save function for real-time contrast. Monitoring includes traditional parameters plus special parameters such as Driving Pressure (DP) and Stress Index (SI), with continuous trend information and discrete events stored and displayed in tables or charts.
Clinical Tools: CBP Modes, Gas Consumption Calculations, and Data Connectivity
The Aeon8800A provides multiple cardiopulmonary bypass (CBP) modes to assist with cardiopulmonary bypass surgery. It also provides medical gas consumption calculations (O₂, N₂O, and agent) and CO₂ production calculations, along with international standard data protocol support for connection to hospital internet centers.
Integrated 2-Hour Battery and Pneumatic Drive
The workstation is pneumatically and electrically controlled, with a DC 24 V, 4 Ah battery providing a minimum of 120 minutes (2 hours) of operation. The central-brake casters support mobility within the operating room environment.
Compact Stainless-Steel Work Surface and Storage
The workstation includes a large stainless-steel work table with LED light, a folding table for additional workspace, and four large-capacity drawers for storing anesthesia consumables and medications. Dual OCC rails allow easy installation of additional devices.
Optional Vaporizers and Accessories
Optional configurations referenced across platform documentation include VP300/VP500 series vaporizers with bimetallic temperature compensation for Sevoflurane, Isoflurane, and Enflurane, a spotlight with LED light source, and an auxiliary folding table.
Technical Specifications
Note: Tidal volume ranges vary by source: 10–1,500 mL is referenced for volume control mode, while the user manual cites 20–300 mL (child), 20–1,500 mL (adult), and 10–1,500 mL (adult optional) for different configurations. PEEP is referenced as 0–30 cmH₂O (optional) in one distributor listing and 3–30 cmH₂O in the user manual. Patient range includes infant to adult in NMPA documentation, with some distributor listings adding neonatal coverage. Confirm the exact configured tidal volume range, PEEP range, and patient population for your unit with the supplier before publishing.
Why Choose the Aeon8800A?
| Clinical or Operational Need | Aeon8800A Solution |
|---|---|
| Need lung-protective ventilation capability | 10 mL minimum VT (volume control), PCV-VG, BIVENT, SI, Static PV loop, recruitment maneuvers, DP monitoring |
| Need precise low-tidal-volume delivery for small patients | 10 mL minimum VT; 0.7 g ceramic valves referenced for weak respiratory effort |
| Need condensation control and circuit durability | Magnesium-aluminium alloy circuit with 35°C heating, autoclavable to 134°C |
| Need intelligent fresh-gas management for low-flow anesthesia | Digital flowmeter, ECO-Optimizer, Driven Gas Auto-Switch |
| Need ventilator-level ventilation modes | VCV, PCV, SIMV, PS + Apnea, PCV-VG, BIVENT, SIMV-VG, SIMV-PC |
| Need comprehensive monitoring and clinical tools | 15.1-inch touchscreen, DP/SI monitoring, CBP modes, gas consumption calculations, trend storage |
| Need battery backup for continuity | DC 24 V, 4 Ah, minimum 120 minutes |
| Need a compact, mobile workstation | 1,403 × 704 × 750 mm, 110 kg, central-brake casters |
| Need storage and workspace | Stainless-steel work table with LED light, folding table, four large drawers |
| Need vaporizer flexibility | VP300/VP500 optional, Sevoflurane/Isoflurane/Enflurane |