Contact via WhatsApp: +81 9022195237
Global Healthcare Medical
Perlove High Frequency Radiography & Fluoroscopy Digital X-ray System PLD5900C #
Perlove High Frequency Radiography & Fluoroscopy Digital X-ray System PLD5900C #
Couldn't load pickup availability
Imported Single Panel with High-Power Generator – Premium Imaging Performance
The PLD5900C features an imported FDXA4343R flat panel detector paired with a powerful 85kW high-frequency generator, delivering exceptional image quality and high output capacity — ideal for hospitals and imaging centers demanding the best in radiographic performance.
High-Frequency Generator for Superior Output
Powered by an 85kW high-frequency generator with a 500kHz inverter frequency, the system delivers stable X-ray production, ultra-short exposure times, and optimized radiation dose for even the most challenging examinations.
Extended Exposure Parameters
-
Tube Voltage: 40–150kV
-
Tube Current: 10–1000mA
-
mAs Range: 0.1–1000mAs
Supports a wide range of diagnostic applications, from pediatric to bariatric and orthopedic imaging.
Canon X-Ray Tube – High Thermal Capacity
-
Model: E7254FX
-
Dual focus: 0.6/1.2mm
-
Anode heat capacity: 400kHu
-
Tube heat capacity: 1339kHu
-
Anode speed: 9700rpm
Engineered for sustained high workload with excellent thermal management and long tube life.
Imported Detector for Exceptional Image Quality
-
Detector model: FDXA4343R
-
Detector size: 17"x17"
-
Pixel pitch: 140μm
-
Pixel matrix: 3040×3036
-
Spatial resolution: 3.7 lp/mm
-
Gray scale: 16-bit
Delivers crisp, high-contrast images with excellent uniformity and low noise for confident diagnosis.
Ergonomic Lifting Bed (30D)
-
Load capacity: 200kg
-
Lifting range: 220mm (500mm – 720mm)
-
Longitudinal travel: 1000mm
-
Horizontal travel: 260mm
Easily adjust bed height for patient comfort, accessibility, and operator convenience.
Comprehensive Positioning Capabilities
-
Tube column longitudinal travel: 2500mm
-
Vertical tube travel: 1300mm
-
Tube arm rotation: ±90°
-
Chest stand vertical travel: 1500mm
Provides full coverage of all standard radiographic projections with minimal patient repositioning.
Fixed Grids for Scatter Reduction
-
Table grid: 18"x18", 103 LP/inch, 10:1 ratio, 100cm SID
-
Chest stand grid: 18"x18", 103 LP/inch, 10:1 ratio, 180cm SID
Ensures cleaner images with reduced scatter radiation for more diagnostic confidence.
Optional Add-Ons for Enhanced Functionality
-
Bucky stand & tube tracking: $2,199
-
AEC (Automatic Exposure Control): $2,229
-
DAP (Dose Area Product): $2,229
-
Automatic image stitching: $2,199
-
Mobile standing pedal: $2,599
Share
