Wondfo Capsule Gastroscope System, 1 Set, Model: GICE-1000 Capsule Gastroscope
Wondfo Capsule Gastroscope System, 1 Set, Model: GICE-1000 Capsule Gastroscope
The Wondfo Capsule Gastroscope System 1 (GICE-1000) is a self-operated, smartphone-controlled capsule gastroscopy system designed for gastric image acquisition and screening in home, clinic, and telehealth settings. It is built around a single-use capsule endoscope (GICE-G-1000) , a portable data recorder (GICE-R-100) , a mobile guidance App (GICE-APP-100) , and a clinician-facing image analysis software (GICE-AISF-100) —replacing the conventional host console and wearable equipment with a phone-connected, cloud-supported workflow.
The system holds China NMPA Class III Medical Device Registration , granted in March 2024 for its intended use in gastric image acquisition and screening support. In a multi-center, open-label, paired-design clinical trial conducted under China's medical device clinical trial quality management standards, the system reported 99.8% gastric anatomical site coverage and 96.8% diagnostic agreement with conventional transoral electronic gastroscopy. These figures describe agreement in image-based findings, not a standalone diagnostic claim—the system is positioned as a screening and image-capture tool, with remote reading and report generation performed by clinicians.
The capsule captures continuous images at approximately 3 frames per second and generates 5,000–8,000 gastric images per examination. Images are transmitted via Bluetooth from the recorder to a smartphone or tablet, then uploaded to a cloud server for remote clinician review. The integrated AI-assisted reading platform is referenced as supporting automated report generation in approximately 15 minutes from image upload to mobile delivery**.
The GICE-1000 is positioned for adults aged 18–70, including health-conscious individuals, those with gastric risk factors, and patients requiring periodic follow-up for chronic gastric conditions. It is not intended for treatment, not a replacement for conventional gastroscopy when tissue sampling or intervention is required, and carries explicit contraindications for patients with swallowing disorders, gastrointestinal obstruction, perforation, stricture, or prior surgery altering GI anatomy, as well as pregnancy, children under 14, and adults over 70.
Key Features & Benefits
Single-Use Capsule Endoscope with Integrated Camera and LED Illumination
The GICE-G-1000 capsule contains an integrated camera and LED flash illumination in a swallowable single-use format. After ingestion, the capsule captures images of the gastric lumen as it traverses the upper gastrointestinal tract, and is naturally expelled in most cases within approximately three bowel movements. No intubation, sedation, or recovery period is involved—addressing the discomfort and anesthesia-related considerations associated with conventional transoral gastroscopy.
Smartphone-Guided Positioning for Eight Gastric Regions
The GICE-APP-100 mobile application provides real-time procedural guidance, instructing the user to change body position in a structured sequence to support image capture across eight designated gastric regions. This body-position-driven acquisition protocol is the mechanism by which the system achieves broad gastric coverage without magnetic steering or a wearable external control unit—distinguishing it from earlier-generation capsule systems that required external equipment.
Bluetooth Recorder and Cloud Uplink
The GICE-R-100 portable recorder receives capsule images and relays them via Bluetooth to the user's smartphone or tablet. The App then uploads the image set to a cloud server, where remote clinicians access the images through the GICE-AISF-100 analysis software for image selection, annotation, and report editing. This decouples image acquisition from image interpretation, supporting telehealth and distributed screening models without requiring an on-site endoscopy suite.
AI-Assisted Reading Workflow with Rapid Report Turnaround
The platform incorporates an AI-assisted image analysis layer that processes uploaded gastric images to support efficient clinician review. Published communications reference automated report generation in approximately 15 minutes following image upload, with the report delivered to the user's mobile device and signed by a clinician. The AI layer is presented as a workflow accelerator—clinician oversight and sign-off remain part of the process.
Built-In Safeguards: Contraindication Screening and Natural Excretion Monitoring
The system includes explicit contraindication criteria covering swallowing disorders, gastrointestinal obstruction, perforation, stricture, fistula, prior GI surgery, severe systemic disease, pregnancy, and age extremes (under 14 or over 70) . The user guidance also includes post-procedure monitoring for capsule excretion, with abdominal X-ray recommended if excretion is not observed within 14 days. These safeguards are part of the screening-oriented design, distinguishing the system from a conventional endoscopic procedure requiring direct clinician manipulation.
Compact, Home-Capable Configuration
The complete system comprises the single-use capsule, the portable recorder, the mobile App, and the clinician software—with no dedicated host console, no wearable vest, and no magnetic control equipment. This reduced hardware footprint supports deployment in clinics, health check-up centers, and home-based screening scenarios, lowering the infrastructure barrier compared with conventional endoscopy suites.
Technical Specifications
Why Choose the Wondfo GICE-1000?